<br /> September 9, 2006
<br /> ENVELOPE SUMMARY
<br /> RE: Eldorado Stone — South
<br /> Seaway Business Park, Bldg E
<br /> Everett, WA
<br /> Heated space applies to Office space.
<br /> Vertical Glazing: U=0.55, SHGC=0.45. Unlabeled glazing - 1/2" space Air, Iow-e1010j,
<br /> fixed, default. Or certified tested assembly per NFRC.
<br /> Doors (Opaque, Exterior): Uninsulated metal, U= 1 .2, default.
<br /> Doors �Opaque, To Warehouse►: Wood, U =0.50, default.
<br /> Other Roof: R-19 batt insulation in wood framing, 24" oc. U=0.048, default.
<br /> Wall Type 1 IOpaque, Exterior, Floor to 9'-0" AFF►: Concrete, min. 6" thick, furred with
<br /> metaf stucls, 3-1/2", 24" oc with R-13 batt insulation, U =0.11, calculated.
<br /> Wall Type 2 (0paque, Exterior, Floor to 9'-0" AFFI: Concrete, min. 6" thick, furred with
<br /> metal studs, 5-1/2", 24" oc with R-19 batt insulation, U =0.085, c�lcula.ed.
<br /> Wall Type 3 (Opaq�e, Exterior, 9'-0" AFF to Structure Abovel: Concrete, min. 6" thick,
<br /> with R-19 batt insulation stickpinned to concrete, U =0.053 calculated.
<br /> Wall Type 4 (OpaGue, 2"'' Flr Warehousel: Metal studs, 3-1/2", 24" oc with R-13 batt
<br /> insulation, U =0.12 default.
<br /> Wall Type 5 (Opaque, Cover Existing OH Door1: Metal studs, 5-1/2", 24" oc vvith R-19
<br /> batt insulation, U =0.091 default.