Laserfiche WebLink
.� <br /> I � <br /> � � • i,:,�, �. ; ,, , ��- �, <br /> FRANKLiN ; , <br /> ENGINEERING , <br /> r�,�(�',;I1;.'nl C(;>1-;�_� ';';r:� <br /> P�CLG°! C;�(�. <br /> � <br /> September 9, 2006 <br /> ENVELOPE SUMMARY <br /> RE: Eldorado Stone — South <br /> Seaway Business Park, Bldg E <br /> Everett, WA <br /> Heated space applies to Office space. <br /> Vertical Glazing: U=0.55, SHGC=0.45. Unlabeled glazing - 1/2" space Air, Iow-e1010j, <br /> fixed, default. Or certified tested assembly per NFRC. <br /> Doors (Opaque, Exterior): Uninsulated metal, U= 1 .2, default. <br /> Doors �Opaque, To Warehouse►: Wood, U =0.50, default. <br /> Other Roof: R-19 batt insulation in wood framing, 24" oc. U=0.048, default. <br /> Wall Type 1 IOpaque, Exterior, Floor to 9'-0" AFF►: Concrete, min. 6" thick, furred with <br /> metaf stucls, 3-1/2", 24" oc with R-13 batt insulation, U =0.11, calculated. <br /> Wall Type 2 (0paque, Exterior, Floor to 9'-0" AFFI: Concrete, min. 6" thick, furred with <br /> metal studs, 5-1/2", 24" oc with R-19 batt insulation, U =0.085, c�lcula.ed. <br /> Wall Type 3 (Opaq�e, Exterior, 9'-0" AFF to Structure Abovel: Concrete, min. 6" thick, <br /> with R-19 batt insulation stickpinned to concrete, U =0.053 calculated. <br /> Wall Type 4 (OpaGue, 2"'' Flr Warehousel: Metal studs, 3-1/2", 24" oc with R-13 batt <br /> insulation, U =0.12 default. <br /> Wall Type 5 (Opaque, Cover Existing OH Door1: Metal studs, 5-1/2", 24" oc vvith R-19 <br /> batt insulation, U =0.091 default. <br /> ��y� <br />