PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City St2ndard �601. <br /> 5. Connecl side sewer per City Slandard#'s 601, 602, 604. <br /> 6. Connect all rooflop downspouts to the side sewer. <br /> 7. Connect rooftop dovmspouts to the drainage system provided for ihis lot. <br /> 8. Rooflop runoff must be discharged to a roof downspout infiltration syslem per Ciry ef Everett Storm <br /> Manual 3-2.62. The approximate size lrench is 3.5'wide, 2'deep and 25' long. See attachment for <br /> rnore details. <br /> �. The contractor must meet with the Public Works Inspector lo discuss potential drainaye routing prior to <br /> beginning the project. <br /> �0. Install erosion conlrol measures as determiried by ihe Public Works inspector, such as silt fence, strav� <br /> bales, swales, or erosion blankefs. <br /> 11. ' Install erosion control measures per City of Everett Standards for srnall parcel; <br /> 12. Remove erosion control measures upon completion of the project prioi lo fi��al approval of thc perrr�il. <br /> 13 All excavated material from foundalion, sidewalk and driveways shall be hauled to an approved, <br /> permitted site. No wasling of maferial is allowed on lhis building !o!. <br /> i 14. No dirl, mud, rocks or debris to be iracked onlo roadway. <br /> 15. No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian lravel. <br /> 1G. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewalk as per City of Everetf Standard Plan#'s 305A& 306 on <br /> this proposal's (rontage as direcled by the Public Works Inspector (i.e. all unus�d driveways and any <br /> broken or damaged area must be replaced). <br /> 1£;. Inslall a Type I concrete driveway per City of Everetl Standard �t307. <br /> 19. Pave driveway from the front property line out to the slreel paving. <br /> 20 Conlact the Water Districl for connecling provisions for this building's water and <br /> s�wer services. <br /> � :'1 !;c�lch basin as per City Slandard Plan#402 with a gas trap per Standard Plan#410 is required (or the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, ihe pressure line musl discharge into a private manhole, then <br /> gravity flow across the public ric�ht•of-way. <br /> 23 A sprinKler syslern is required for lhis bi!i!ding in compliance with lhe requirements of NFDA Standards <br /> 13D. <br /> FOR PJBLIC A��ORKS IFJSPEC7lON. CNLL RANDI' AT 425-339-7-103 I CLIFF AT 425-339-7404 <br /> � .. ��� <br />