Laserfiche WebLink
COMPLIANCE � � � � � � � ' <br /> HEOUIRED � <br /> INSPECTION IMPORTANT: Disregard topics that don't describe your bullding or equlpment.DO NOT <br /> APPflOVED P�ace checks In the two lett columns. � <br /> r� 1 r K7i7,r�'�' � <br /> O p �Alrtiow from habitable rooms to whole-house fan ensured by undercut doors or grills (VIAQ,S.302.6.4) <br /> O p �i Loosetlll Insulatlon OK fl (S.502.1.4.5): <br /> pmaximum ceiling slope s_.3 �n 12 ' <br /> pz 30"ot clear distance irom top oi bottom chord to underside ot roof sheathing at the roo( ridge. <br /> O O Q6 mll biack polyethylene ground cover, lapped 12'at joints and to(oundation wall <br /> a o QCiearances shall meet Iisied minimums behveen Insulation and (S.502.1.4.3): <br /> p chimney p Non-IC rated recessed lights: 1/2"to combustables,3'to insulation. <br /> p p �tilc hatch shall be insulated to required ceiling R-value and is weatherstripped (S.502.1.4.4) <br /> � O AYtic access shall ha�ve wood dam or equivalent to retain loose fill insulation in attic (S.502.1.4.4) <br /> O p Il exterlor doors (,zcept 20 minute doors) shall be weatherstripped(S.502.4.3). <br /> p O � Service hot& coid water plping shall be insulated to R-3(S. 503.11) <br /> p p Ssrvice recirculatlon hot w�ter plping shall be insutated to Table 5-12 levels. <br /> O O hertnostat provided for each HVAC system with range oi 55-75' F.(heating) (S.503.8.1.1). <br /> O 0 Readily accesslble,automatic or Manual means provided to restrfct or shut-oti Heating Input to each <br /> zone or iloor during periods not requiring heat (S. 503.8.3.1 j. <br /> � 0 � Controls for backup heat prohibit similtaneous operation cf the primary system (S. 503.2.2(3)). <br /> p p z Mechanlcal ventllation systems shall have proper timers, and/or switches(S.302.3). <br /> p p s Mechanical ventllatlon duds shall have insulation 2 R-4 in unconditioned spaces(VIAQ,S.302.5) <br /> ❑ O Mechanlcal suppiy d�cts in conditioned spaces shall have z R-4 insulation (VIAQ,S.302.5) <br /> p p a upply duds shall have volume dampers, or the equivaient, to balance system(S.503.6). <br /> p p Suppiy and return air ducts shall liave sealed duct joints in unconditioned spaces (S. 503.10.2). <br /> O p � HVAC plenums,supply,and return air ducts shall have R-8 insulation(Table 5-11,Ail optiona) <br /> o o a Electric water heater(s)shall have(S.504.2,1, 504.3,504.4) : <br /> ❑ separate power � • shut-oH ❑ 1987 NAECA Lable on tank <br /> ❑ noncompressible R10 pad (unheated spaces only) ❑ Tertperature setting s 120 F. <br /> O O 9 Showers and lavatorles shall limit fbw to s 3.0 gallons/minute (S. 504.8.1). <br /> p p Swlmming pool(s) (S.504.5) shall have: <br /> areadily accessible OWOFF switch (pump, heater) ❑ Pool cover ❑Piping Insulated to S. 503.11 <br /> p O � Fireplace(s) (VIAQ,S.402.3)shall have: <br /> a 6 square inch combustion air supplyduct w/operable damper, directly conneded to the iire box <br /> p Tight titting glass or metal doors;or Ilue draft induction tan. � Tight filting flue damper. <br /> O O � Solid fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br /> o Tight liriing glass or metal doors <br /> p Outside combustion air source directly connected to the fire box <br /> a Exceptbn: Non-direct, 4'dfameter, dampered, combustfon air source: ailowed only 1or(1) new stove <br /> installations in existing homes where obsirudions preclude direct combustbn air, or(2) Cemrai <br /> heating systems bcated in unheated spaces. <br /> O C� Three moMh, etched track,tadon monRor, prirried instruclions, and an Inlormation sheet shall be <br /> supplied by the builder to each single tamily dwelling and to each ground tloor unit oi mulli-family dwellings <br /> (VIAQ, S.502.2.1). <br /> WSEC FIna1 phase requlrements: <br /> Inspected by oate <br /> Page 6 of 6 - <br /> _..�._ __ :. .-_.__- <br />