|
- �
<br /> .� a����" ' , .
<br /> <:OMR.i.4NCE ��,�'a�',,, ' $ + �....�.,
<br /> ' t'REUuir7EL' 1.s��" '�'�'3,::; �', ,�- �
<br /> �'�l� i�*'�` �r
<br /> � s � �, . _ ,, �. .
<br /> �. INSPEC�ION `.., �z ,.�. .. � � .. . � .
<br /> APPPJVED� �MPORTANT: DQ_dQI piace checks In the two left columns.
<br /> _`�, J
<br /> ' ' '� �, " ,,'<?��'
<br /> � O �Exposed foam insulation shall comply as foliows (S. 502.1.4.7);
<br /> ❑ Protected with metal or piastic flashing, or other suitable m2teriai that extends below grade.
<br /> ❑ Insulation is approved for sub-grade, extericr use and properly installed.
<br /> O QAir(low between fresh air ports and ihe whole-house fan ensured by undercut doors/griils(VIAQ,S.302.6.4)
<br /> � �l.00seflll Insulation OK it (S.502.!.4.5):
<br /> p maximum ceiling siope not > 3 in 12
<br /> pa 30"of clear distance irom top ot bottom chord to underside oi reoi sheathing at the roof ridge.
<br /> p s 6 mil black polyethylene ground cover, shall be iapped 12" at joints and extend to foundation walt
<br /> p e Clearances shali meet listed minimums between insulaiion and (S.502.1.A.3):
<br /> ❑chimney pNon-IC rated recessed lights: 1/2"to combustables,3"to insulation.
<br /> O � Attic hatch shail be insulated to required ceiling R-value and is weathersiripped (S.502.1.4.4)
<br /> ❑ Attic access shali have wood dam or equivalent to retain loose fill insulation in attic(S. 502.1.4.4)
<br /> p e All exterior doors (except 20 minute doors) shall 6e weatherstripped (S.502.4.3).
<br /> O a Service hot & coid water plpinp in unconditioned spaces shall be insulated to R-3(S. 503.71)
<br /> O � Service reclrculatlon hot water piping in unconditioned spaces shall be insulat�d to Table 5-12 levels.
<br /> O O z Heat pump thermostat shall have progamabie capabiiity(S. 503.8.3.5)
<br /> ❑ z hermostat provided for each HVAC system with range o(55-75' F.(heating) (S.503.8.1.1).
<br /> p Readtly accesslble,a.tomatic or Manual means provided to resirict or shut-off Heating input to eacli
<br /> zone or floor during periods nct requiring heat (S. 503.8.3.1).
<br /> p s ontrols for backup heat prohibit similtaneous operation of ihe primary systEm (S. 503.2.2(3)).
<br /> p s echanical venttlation system shail have proper timers, and/or switches(VIAQ, S.302.3).
<br /> p � echanlcal ventllatlon ducts shall have R-4 insulation in un�npditi4¢ed spaces (VIAQ,S.302.5)
<br /> p a echanical ventllation supply ducts in�onditionad spaces shall have R-4 insulation (VIAO,302.5)
<br /> p a upply ducts shall have volume dampers, or the equivalent, to balance system (5. 5D3.61.
<br /> p a upply and return air ducts shall have seaied duct joints in unconditioned spaces (S. 503.10.2).
<br /> ❑ r VAC plenums,supply, and return aly ducts shall have k-8 insuiation (Table 5-11, All options)
<br /> p � 2 iectric water heater(s) shall have (S.5042.1, 504.3, 504.4) :
<br /> ❑separate power shut-off ❑ igg7 NAECA Lable on tank
<br /> ❑noncompressible R10 pad (unheated spaces only) 17 Temperature setting s 120 F.
<br /> ❑ �howers and lavatorles shall limit tlow to s ;�gallons/minute (S. 504.8.1).
<br /> 0 O �wimming pools(S.504.5) shall have: 2,5
<br /> p readily accessible ON/OFF switch (pump, heater) pPool cover ❑Piping insulated to S.503.11
<br /> O QAII tireplaces (VIA�, S.402.3) shali have:
<br /> ! G square inch combustion air supplyduct w/accessible darrper directly connected to the fire box
<br /> lTight fitting giass or metal doors. p Tight fitting flue damper
<br /> ❑ s Solfd fuel burning appllance(s) (VIAQ, S. 4022) shall have:
<br /> �Tic�ht fitting glass or metal doors
<br /> o Outside combustion air source directly connected to the tire box
<br /> o Exception: Non-direct, 4" diameter, dampered, combustion air source:allowed only for(1) new stove
<br /> installations in existing homes where obsiructionsprecludes direct combustion air,or(2) Central
<br /> heating systems Iocated in unheated spaces.
<br /> ❑ � Tliree month, etched track radon monitor, printed instruclions, and information sheets shall be supplied
<br /> to the single lamily dwelling or first fioor units ot multi-family dwellings by the goaasz{.oeairaWor(VIAQ,S.
<br /> soz.z.i�, J�R�tra�cT��+
<br /> WSEC Fina!phase requirements:
<br /> Inspected by: Date
<br /> Page 6 ot 6 —
<br />
|