My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2131 LAKE HEIGHTS DR 2016-01-01 MF Import
>
Address Records
>
LAKE HEIGHTS DR
>
2131
>
2131 LAKE HEIGHTS DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/19/2017 12:47:52 PM
Creation date
2/19/2017 12:46:59 PM
Metadata
Fields
Template:
Address Document
Street Name
LAKE HEIGHTS DR
Street Number
2131
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
351
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> 24. Fire lanes mus[ be oroeided as required in Evere[t Municipal Code 46.44. Fire lanes must be <br /> identified M• red curbs with white stenciline sca[ing "NO PARKING - FIRE LANE" and <br /> �•enical siens scatine "NO PARI:IIG - FIi2E LANE- TOW AWAY ZONE." L.ocation must <br /> be appro��ed b}� the Fire Marshal. <br /> 'S. Based upon 31.000 square fee[ of Type 111-N, sprinklered construc[ion, the fire flo.�� <br /> requirement is 1.575 GPM. <br /> 26. A fire hydrant is required u�i[hin 200 driving fee[, bu[ not closer than 50 feet, of every <br /> s�rucmre. 7'«�o additional hvdrams must be installed. Tlie location oC the hydram must be <br /> approved by the Fire Dlarshal. <br /> 27. An apptoved automatic suppression system shall be provided as required by Ciry Ordinance <br /> 1902-92, Chapter 16J6, of the Evereu 1�7unicipat Code. <br /> Plans for am� such s��scem must be submitted to [he Building Departmen[ snd [he Everet[ Fire <br /> Department for examina�ion and approval. Such plans must include plans for the underground <br /> mains [hai aill supply ihe sprinkler system. <br /> Above ground sprinkler pipine must be hydrostatically tested as established in NFPA Standard <br /> 13. Underground pipine mus[ be hydrostaticall�� tesied and tlushed as established in NFEA <br /> S[andard ?4 for pri��atc fire mains. All such tests must be w�imessed by a Fire Department <br /> inspec�or. Call 2�i-81�3 [o make an appoinement for inspec[ion. <br /> Convactors' materials and [est cettificates must'oe submit[ed to the Everett Fire Department <br /> prior to issuance of anp Cenificaies of Occupancy. <br /> CaU 257-8123 for more informa[ion. � <br /> ?8. An approved aucoma�ic fire de[ec[ion system mus[be provided as required by Ordinance 1902- <br /> 92, Chapter 16.76 of the Evere[t Municipal Code. ' <br /> t <br /> Plans for such svstem must be submi[ced [o [he Fire Marshal for review� and appm��a3 prio� �o <br /> inscailarion. Subminal shall include cuc sheecs of all equipmen[ in[ended for use. Appropriate <br /> vip tesa, witnessed b�� a Fire Deparunem inspector. shall be performed, alon= with a <br /> cettificace of comple[ion, prior to final ac_:ptance of[he s��stem. <br /> Fire alarm svstems shall be installed according to NFPA Scandard 7�. <br /> _ ..Fire alarm s��scems shall.be installed under permi[ of the Cit}� of Everett Buildinc Deparunent. <br /> Electrical inspections and approval are required prior to calling for acceptance tesa. Call <br /> 257-8810 for permit informacion. <br /> 29. A porable fire ex[inguisher with a minimum UL racing of 2-A:10-B:C mus[ be provided wi[hin <br /> 75 feet travel distance on aU floors of each building during construction and prior to <br /> occupanc}�. <br /> 30. KiICh� - ]nstall a fire e�tinguisher with a UL rating of 40-B:C within 30 feet of[he grill and <br /> deep fn•ers. <br /> 31. Commerci�.l Cooking O ra�i nc - A vencilatinc hood and duct syscem with an approved <br /> automatic fire-extinguishine system shall be provided in accordance with the Mechanical Code <br /> (or commercial-type food hea:-processine equipmenc that produces grease-laden vapors. <br />
The URL can be used to link to this page
Your browser does not support the video tag.