My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5904 LARIMER RD 2018-01-02 MF Import
>
Address Records
>
LARIMER RD
>
5904
>
5904 LARIMER RD 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2022 9:47:02 AM
Creation date
2/19/2017 1:13:30 PM
Metadata
Fields
Template:
Address Document
Street Name
LARIMER RD
Street Number
5904
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br />REQUIRED <br />INSPECTION IMPORTANT: Su I Information and check a ro rlate clrc!es In the shaded boxes. <br />APPROVED PP y PP P <br />Disregard topics the: don't describe your building or equipment. DO NOT placo checks in <br />the two left columns. <br />•,ems , � , I•p, rt �„ �" i.: _ <br />9rr-n <br />O n I Exhaust ventilation shall be provldPd for each dwelling unit (VIAQ, S 303) <br />Location Minlmum at .25 w.g Mfr./model Fan label <br />Kitchen fan 1 <br />100 CFM <br />Bathroom fan(— —) <br />50 CFM <br />Bathroom fan( ) <br />50 CFM <br />Bathroom fan( ) <br />50 CFM <br />Laundry fan 1 <br />50 CFM <br />t(JOS0 CFM (1-2 bedrms) <br />18 Whole house fan Q 80 CFM (3 becirms) <br />(choose one) <br />Q 100 CFM (4 btedrms) <br />Whole house tan: Location A�T Sane rating_ _(s 1.5 if attic fan closer than 'to <br />ceiling <br />( Whole house fan is listed4abled "for Continuous use": <br />Q Whole house fan wiring for control routed to centra! to <br />cation dehuml���� sfaonly}$., <br />O rs Whale house fan also serves as a kitchen or bath spot fan.;; s Q No <br />(if a spot tan is designated as a whole }louse fan, the capacity shall be the larger CFM requirement.) <br />O Whole house fan shall tuncontinuously: Kitchen rate 25OFM: Bath &laundry rate 20CFM <br />O I= r Integrated forced -air furnace ventilation (VIAQ Code, S. 303.1.2(b)) shall be synchronized with a <br />whole house fan to supply fresh air to the dwelling: Q Yes Q No <br />Q if yes a 6" die, eteroutside air inlet duct w/ motorized damp7 shatl run from the buking <br />exterior to the furnace return plenum and limit the ventiltion rate to between .35 - .5 ACH, <br />Q Modifications to the above integrated forced air system may require performance testing,. ln.WTI <br />manner acceptable to the building official, to demonstrate .35 - 5 Air Changes/Hour ° <br />0 Mechanical ventilation tan ducts shall be z 4" and properly sized (VIAQ, Table 3-3). <br />O QFresh air shall be provided for each dwelling unit as follows (VIAQ, S. 302.6.1): <br />ch bedroom: Tested, screened, controllable, through -wall port (Z'4 Sq 1n;} to iha exterior <br />I< ill recreation room: One wall port as specified for bedrooms. <br />II —Other enclosed 'habitable" rooms: One wail port as specified for bedrooms. <br />vetall living area: One v;all port as specified for bedrooms. <br />M O 'a OR QCentral forced air furnace which delivers outside makeup air through the ducting system <br />QReces lighting fixtures (S. 502.4,4) shall comply w/ one or more of the following: <br />C rated, no slots or holes in cans, caulked or sealed between can and ceiling <br />C ) IC rated with ]able certifying an ASTM E283 tested airieakage s 2,0 CFM <br />Q Any UL listed fixture enclosed by a 1/2" gypboard box or other manufactured box <br />w/ 1/2" clearance to combustibles, and 3" clearance to insuiati0n. <br />WSEC Ft rming phase requirements: <br />Page 4 of 6 Inspected by _ - _ Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.