Laserfiche WebLink
Case # 3A: <br />Retained Soil Height = 10'-0" <br />Soldier Pile Spacing = 8 Feet O.C. <br />Required Pile section = W 18 x 46 <br />Shaft Diameter = 30" <br />Required Embedment l.cngth = 17' <br />Case # 4: <br />Retained Soil Height = 12'-0" <br />Soldier Pile Spacing = 8 Feet O.C. <br />Required Pile section = W 18 x 76 <br />Shaft Diameter = 30" <br />Required Embedment Length = 20' <br />