My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7825 LARIMER RD 2018-01-02 MF Import
>
Address Records
>
LARIMER RD
>
7825
>
7825 LARIMER RD 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2022 10:14:09 AM
Creation date
2/19/2017 1:21:24 PM
Metadata
Fields
Template:
Address Document
Street Name
LARIMER RD
Street Number
7825
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Qrfist IPesidence <br />Energy Code Evaluation - Component Analysis <br />1995 Washington State Energy Code <br />Analysis is based on a 500.5 s.f addition. Of this area, 410.5 s.f. are on the main level <br />and the remaining 90 s.f is on the upper level. The analysis is done by calculating the <br />Target UA value (UAi). and a proposed UA value (UA). These calculations are done by <br />using the provided equations (1 and 3) from chapter 5 of the 1995 Washington State <br />Energy Code. The proposed UA is to be less than the UAT. The calculations and analysis <br />is as follows. Please see the attached copies of the code charts for reference to the <br />proposed values. <br />UAT = UwAw+ UnowAnow _F UcAc + UFAF 4 UecAac ' 11ccA(.c + UI)AD + FSPs <br />UA = UwAw+ UnowAnow + UaAc + UFAF + UtzcAxc + UccAcc , UDAD + .,Ps <br />UA UAT <br />U <br />= Thermal resistance value <br />A. <br />= Area in square footage <br />W <br />= opaque above grade wall <br />BGW * <br />= Below grade wall <br />G <br />= glazing <br />F <br />= floor over unconditioned space <br />KC <br />= roof / ceiling <br />CC <br />= cathedral ceilings (single rafter / joist vaulted) <br />D <br />= opaque door <br />I's . <br />= lineal feet of concrete slab perimeter <br />* These areas are not applicable in the following analysis. <br />Tn,.of VA Annlude <br />UA = <br />Area <br />S . Ft. <br />UVA„IF <br />Total <br />Remarks <br />UwAw <br />Walls <br />397.8 <br />.061 <br />24.2658 <br />All of the listed U values <br />are based on 1995 WSEC <br />Table 5-1 for <br />"Other Fuels in <br />Climate Zone 1" <br />U(;An <br />Glazing <br />500.5x l5*/, <br />.65 <br />48.79875 <br />U:A <br />Floor <br />410.5 <br />.041 <br />_�fi.3305 <br />UacA c <br />Roof <br />410.5 <br />.036 <br />V.778 <br />Uc : <br />Cathedral <br />90 <br />.034 <br />3.06 <br />U )A <br />Doors <br />1 30 <br />.40 <br />12.0 <br />UA = <br />1 119.73305 <br />
The URL can be used to link to this page
Your browser does not support the video tag.