1995 Edition <br />Washington Slate <br />Energy Code <br />TABLE. 5-1 <br />TARGET COMPONENT VALUES FOR GROUP R OCCUPANCY <br />Electric Resistance <br />Other Feels <br />Climate Zone <br />Climate Zone <br />Com ,ment <br />I 2 <br />1 2 <br />Glazing %Floor Area <br />15% <br />15% <br />15% <br />15% <br />Glazin 1-1-Factor <br />L! = 0.400 <br />U = 0.400 <br />U = 0.650 <br />_ <br />11 = 0.600 <br />Doors <br />U = 0.200 <br />U = 0.200 <br />U = 0.400 <br />_ <br />11 = 0.400 <br />(R-5) <br />(R-5) <br />(R-2.5) <br />(R-2.5) <br />Ceilings <br />Attic <br />U=0.031 <br />U=0.031 <br />U=0.036 <br />U=0.031 <br />(R-38) <br />(R-38) <br />(R-30) <br />(R-38) <br />Single RzPcrl <br />U = 0.034 <br />U = 0.034 <br />U := 0.034 <br />U = 0.034 <br />Joist Vaulted <br />R-30 <br />R-30 <br />R-30 <br />_ IR-30) _ <br />Walls <br />U = 0.053 <br />U = 0.044 <br />U - 0.(K,11 <br />U - 0.0621 <br />(R-19A) <br />R-19+5A) <br />(R-19) <br />(R-19) <br />Floors <br />U = 0.029 <br />11 = 0.029 <br />U = 0.041 <br />U = 0.029 <br />_(R-30) <br />(R-30) <br />-19) <br />__AR-30) <br />Slab on Grade <br />F = 0.54 <br />F = 0.54 <br />F = 0.54 <br />F - 0.54 <br />Slab R-Value <br />(R 10) <br />(R-10) <br />(R-10) <br />(R-M) <br />Below Grade Interi3r <br />Wall R-Value <br />R-19 <br />R-19 <br />R-19 <br />R-19 <br />2' Depth: Walls <br />U = 0.043 <br />U - 0.043 <br />U = 0.043 <br />_ <br />U = O.043 <br />Slab <br />F=0.69 <br />F=0.69 <br />F=0.69 <br />F=0.69 <br />3.5' Depth: Walls <br />U = 0.041 <br />U = 0.041 <br />U = 0.041 <br />U = 0.041 <br />Slab <br />F=0.64 <br />F=0.64 <br />F=0.64 <br />F=0.W <br />7' Depth: Walls <br />U = 0.037 <br />U = 0.037 <br />U = 0.037 <br />U = 0.037 <br />Slab <br />F=0.57 <br />F=0.57 <br />F=0.57 <br />F=0.57 <br />Below Grade Exterior <br />R-Value <br />R-10 <br />R-12 <br />R-10 <br />R-12 <br />1 <br />_Wall <br />.. Depth: Walls <br />U = 0.070 <br />U = 0.061 <br />U = 0.070 <br />U = 0.061 <br />Slab <br />F=0.60 <br />F=0.60 <br />F=0.60 <br />F=0.60 <br />3.5' Depth: Walls <br />U = 0.064 <br />U = 0.057 <br />U = 0.064 <br />U = 0.057 <br />Slab <br />F = 0.57 <br />F = 0.57 <br />F =- 0.57 <br />F = 0.57 <br />7' Depth: Walls <br />U = 0.056 <br />U = 0.050 <br />U = 0.056 <br />U = O.OSO <br />Slab <br />F = 0.42 <br />F = O.A2 <br />F = 0A2 <br />F s 0.42 <br />1Log and Solid'rimbcr walls have if minimum avenge thickness of 3.5" aro <br />exempt from wall target UA and proposed UA calculations. <br />45 <br />t.i <br />