My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
500 LAUREL DR 2016-01-01 MF Import
>
Address Records
>
LAUREL DR
>
500
>
500 LAUREL DR 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2017 12:48:45 PM
Creation date
2/19/2017 1:37:04 PM
Metadata
Fields
Template:
Address Document
Street Name
LAUREL DR
Street Number
500
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
152
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Geotechnical Engineering Study Page 4 <br />00-2267 Three Story Addition - 500 Laurel Street, Everett <br />January 31, 2001 <br />for use in concrete floor slab design, or axial, lateral and uplift <br />capacities for driven-in-place steel pin-piles to develop <br />supplemental foundation support, if appropriate, <br />■ Evaluation of the potential magnitude and rate of total and <br />differential settlement likely to occur under the imposed <br />building addition dead and live loads, <br />■ Provision of geotechnical recommendations for design of <br />buried below ground retaining walls to include active and <br />passive equivalent fluid weights and a fictionai resistance <br />coefficient, <br />■ Evaluation of the stability of the sites' steeper westem <br />perimeter bluff slope under static and dynamic (earthquake) <br />conditions, <br />■ Evaluation of the sites' potential for liquefaction under <br />earthquake conditions and, if appropriate, an estimate of the <br />potential magnitude of liquefaction se�tlement that might <br />occur, <br />■ Provision of geotechnical recommenaations for seismic <br />design, including the 1997 UBC criteria for site profile, <br />horizontai acceleration, and Ca and Cv coefficients, <br />■ Development of a geotechnical opinion regarding the <br />appropriate minimum setback distance from the nearby <br />western bluff slope, <br />■ Provision of geotechnical recommendations for short and <br />long term site drainage and erosion control measures, and <br />■ Provision of four copies of a final �vritten report summarizing <br />the above informatio�. <br />13 <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.