Laserfiche WebLink
q � e <br /> COIdPUANCE �� �: r ,..r< .�: ..r::: s �:3m �r. '� �� f�. � <br /> : } p <br /> .:. . , .. : .. <br /> tr�i :� tS 4�{...�t Sh� � <:. • <br /> REOUIRED � . . . - � � . . � ' - "•.•��. <br /> 3.. _,..�..<: ....i. <br /> :. - . -�: �._ .� ,r:. . _:; � : .•.:. �� '. �� .. ..< �:.. . ... .._.w. �........ ..:.... ... . ....... .:. <br /> INSPECTION �MPORTANT;Supply information and check approprlate clrcies In the shaded boxes. <br /> APPpOVED DlsreBard t�opics that don't describe your bullding or equlpment.D9�QI place checks in <br /> the two lett columns. <br /> s <br /> . , . , <br /> _ _. . <br /> O O �< Prescriptive exhausK vendlatlon exhaust requirements for each dwelling unit(VIAQ,S. 303): ` <br /> .� . ,.�� <br /> < .... . ,. ,. , ,.., . , � , <br /> . . . Mlnlmum(.25w.g.) MfrJmodel Fanlabel(.1WG) <br /> ,:: Kitchen fan 100 CFM ° � <br /> ;' Bathroom fan( .) 50 CFM <br /> I Bathroom tan( ) 50 CFM • � ' <br /> ,jL,...;?'., <br /> ? Bathroom tan( ) 50 CFM <br /> Laundry fan 50 CFM <br /> 50 CFM (1-2 bedrms) . <br /> 15 ' � ' � 80 CFM (3 bedrms; Y' <br /> .. • . <br /> 100 CFM (4 bedrms) <br /> ".Whole`h6use fan: Locaticn Sone raiin9 " r< t;5 if aUic tatr cioser than 4'lo <br /> celiing) I ' <: ' <br /> Q Whole house fan is ifsted/labled"for Corrtinuous use": <br /> ('� Whole house fan wiring#or control routed to central location (dehumid)stafonlyl. ; <br /> O O +s Whoie house fan alsa Serves as a kltchen.pr bath spot fan. �'Yes; � No <br /> (spot tan designated as a whple houselan sfiali meet whote house fan requ3remenis.) <br /> � O » Spot fan!sn't suRable for Whole house`tan and must be seperate Q Yes Q No <br /> O � 1e SNhole house tan shatl run crontinuous'ry; Kitchen(25CE'M), Bath 8 laundry(20CFMj�Yes Q No <br /> p O i9 Integrated forced•alrfumace venUSation(see�footnote)(VIAQ Code;S.I303.7.2{b�)shatt hs <br /> - synchronized witti a whole hous�fan to suppiy iresh air to tba tJwelling: � Yes � No f � <br /> Q Jt yes, a 6"diameter out�ide air;nlet duct wi mcrorized damper shail run from the builcJing <br /> ezterior to the furnace return plenum and timit the venifltion rate tobetween.35-.5 ACH, �i <br /> 0 Modifications [o the above integrated forced air svstem may require pertorrnance testing, in a <br /> manner acceptable to the buikling;oiticiai, io demonstrate.35-.51 Rfr Changes�lout. ' <br /> 'Five bedrooms o�large[requires a designed whole house tan system (Rate is .35 -.5 ACH) <br /> O O °Q Mechanlcal ventllatlon fan ducts shall be 2 4"and properly sized (VIAQ, Table 3-3). <br /> . . -. <br /> O C7 �Q Fresh air shaif be proWded for each clwelling unit as foilows (UTAQ,S.302.6.Y}',; <br /> ach bedroom: Tested, screened, controliatite, through-wall port (i 4 Sq. ln,}Ito ttie ezterior. <br /> O ach recreatlon room:One wa11 port as specified for bedrooms. <br /> tfier enc;osed "habitable"rooms: One wail port as specified ior bedrooms,' <br /> verall living area: Oqe wall port as spe,9ied for bedrooms. <br /> � O QOR �Integrated forced air furnace which delive�s outside makeup air through the dacting'systam <br /> WSEC Framing phase requirements: <br /> lnspected by Date page s <br />