Laserfiche WebLink
Paqe 2 . E't«'Yt',_. �; <br /> October 29, 1975 - � , <br /> '°; ) <br /> __.. <br /> 7. Exits shall be illuminated with light having an �•----� <br /> intensity of not less than one foot candle at floor <br /> level as set forth in Section 3312 (a) . <br /> 8. Exit signs shall be provided in compliance with ' <br /> •Section 3312 (b) . <br /> 9. Exit doors shall not be provided with a latch or <br /> lock unless it is panic hardware; in compliance <br /> with Section 3316 (a) . � <br /> 10. Facilities for the physical handicapped shall be � <br /> provided in strict compliance with the American <br /> National Standards Institute Inc. , Document ANSI <br /> A117.-1961 (reaffirmed 1971) as adopted by the State <br /> of Washington. See attachment. <br /> 11. All wood finishes on walls shall be finished for <br /> . class III 'flame spread� rating. <br /> 12. Complete plans and details of the hood and vent • <br /> system shall be submitted for review and approval <br /> prior to installation. A seperate permit is required <br /> for this item. . <br /> 13. Submit Mechanical and Electrical plans for approval. <br /> A buildir.y- pez••.iit will be issued upon receiving a reply bx <br /> � return mail c, personal deliverance, stating compliance <br /> with this plan check letter. - • <br /> Yours truly <br /> � � ��� <br /> � Jamie G.' Johnson <br /> Inapection Supervisor <br /> JGJ:eb <br /> enclosure <br />