Laserfiche WebLink
_- -.. . .. <br /> i <br /> . • • I <br /> . , <br /> . � �,. �::�:_ I <br /> _ � <br /> ; <br /> ; <br /> ; � <br /> . , <br /> ; -- �-� <br /> . .�� ,, <br /> ���:_�._. <br /> April 19, 1972 <br /> fhe Evergreen <br /> un oF <br /> everett <br /> CITY MI�LL � S!�•I��f <br /> Metropoliton ConSttLLCt�O[1 CO. [y[11(TT. WAtMINOTON <br /> P.O. Box 778 • . 'c:°� <br /> � in��[cnoH ov�err+cnr <br /> Everett�, Washington 98206 <br /> ' Re: Plan Correction List <br /> Alterations to Resturant for " <br /> Everett Realty Building <br /> Hewitt Avenue & Colby <br /> Everett, Washington � • , . � <br /> Gentlemen: <br /> The subJect drnwings hace bcen reviewed and the following corrections . <br /> must be made to comply with the Uniform Building Code, 1470 Edition. <br /> 1. All walls to have 5/S" x rated G.FI.B. on cuch side. See mezzanine <br /> walls. <br /> ' 2. Basement must have 1-hour separation from ist floor including <br /> ' ceiling. _ <br /> 3. Usablc attic space must have 1-hour separat•ion from ist floor. <br /> 114. Openings within 20 feet of property line shall be 1-hour with <br /> ce:f closins devices. Door on alley nvst co:nplp. <br /> 5. Doors cannot project into alley. • <br /> Y 6. A 1-hour ceiling is required. All 3ucts aud recessed light fixtures <br /> must be 1-hour rated or protected f�r 1-hour construction. . <br /> 7. An occupancy sign must be posted at front door "I18 Occupancy": <br /> 8. The Resturant requirea a second exit. Exit thxv kitchen is not <br /> permitted as a second exit. <br /> 9. All exit doors must swing in line o:" egress. <br /> 10. Corridors stiall be a minimum of 44 inches. <br /> ].1. Stairs shall have a handrail. <br />