Laserfiche WebLink
c c <br /> Meg Haley <br /> From: Meg Haley <br /> Sent: Monday, November 15,2010 11:31 AM <br /> To: 'wildbill44cr@yahoo.com' ���(Q-G p� l <br /> Cc: 'info�downtowndennis.com' <br /> Subject: Plans need clarification on use: fumiture and response � <br /> Importance: High I <br /> Dear eill, <br /> I received the plans dated Noveriber 12th. What is the proposed use of the space? The second submittal is still <br /> incomplete,and the second corrections letter is attached. <br /> Since there is only one usable exit,the maximum public occupant load is 49. The occupancy should be shown on the <br /> drawings with text and furniture so that the occupant load can be determined. <br /> The occupant load is based on use and square footage. <br /> • As a grocery, 1470 square feet can be public area (30 sf per person). <br /> • As a dining/seating area,a wall would have to be constructed to limit the public area to 735 square feet, if the <br /> public area is table and chairs,or even less area, if standing is expected(15 sf per person). <br /> o As a dining/seating area,two toilets(male and female)would be required unless the square footage of <br /> the public area is reduced to 450 square feet. <br /> Please see attached second corrections letter,and contact me at your earliest convenience if you have questions or <br /> concerns. <br /> � <br /> 3137_OOl.pdf <br /> ^'Meg <br /> M.tewr.N�we .:� . _. � . . . _ , r., . <br /> CIryalEvcmtt ...`2��.�:.! . `+•'" ,.�.'I i �. _.d I mholnyaC_C�e�iClt.wa_us <br /> 1 <br />