Laserfiche WebLink
^ <br /> Pr/6�L/C iYORKri <br /> ���� <br /> January 30, 1995 <br /> Roga Waid ' <br /> The Moffat Group Partnership <br /> 8281 NE Seaview Avenue <br /> Indianola WA 98342 <br /> Subject: Proposed Theater Floor Pian on Hewitt Avenue <br /> Dear Mr. Waid: <br /> The ramping, as proposed, would not be acceptable by this department for the <br /> following reasons: <br /> ! 1. WAC 51-20 Sec6on 3106(d)3 requires ramp s to be no steeper than 1:12. <br /> Conversadon with the State Building Code Council advises us that this is a <br /> substantial remodel and change of usc, both of which require full compliance. <br /> i Also, as you know, it is common for pcople confined to whedchairs to want ro <br /> be xlf-sufficient and not dependent on the a�d of an usher. <br /> 2. UBC 3307(c) requires that no ramp be steeper than 1:8. <br /> _ _ The restroom layout, as Proposed, does not comply with WAC 51-20 Section 3105(b)2 <br /> � which calls for an access►ble water closet in each toilet facility. <br /> ! <br /> , The 6'-4" of headroom in the projection room will be aoceptable to this department. <br /> If I can be of further assistance, please do not hesitate to call me at 259-8810. <br /> Sincerely, <br /> �i'✓ " ��"�' <br /> Steve Miller <br /> Associate Engineer <br /> �ar..n <br /> CITY OF EVERETT•3200 Cedar Street• Everett,WA 98201 • (206)259-8800• Fax(206) 259-8856 <br />