Laserfiche WebLink
� . __ <br /> � ,,TRUCTURAL DESIGN ASS JIATES, INC. <br /> �� , � CONSULTING ENGINEERS <br /> (t 56J0.19BTNST.SW . POBOrS.Mfi <br /> +P LYNYWOOD.W19P0<6 • PHONP.I�O6�l]S�IUe <br /> S <br /> � March 17, 1987 <br /> �� � � <br /> Steve Galey <br /> C.H.I.P.S. <br /> 3002 Wetmore Avenue <br /> Everett, WA 982� �--____ <br /> subject: Roof IIeam Inspection <br /> 1922 Hewitt Avenue, Everett, Wash. <br /> Our Ref. : N81-217 <br /> To Whom This may concern: <br /> At the request of Mr. Steve Galey, this office made an <br /> inspection of the above referenced two story structure on <br /> March 4, 1967. At the time of the inspection the building <br /> was undergoing remodeling construction, and a bearing wall <br /> had to be replaced with a beam, tt�e design of which was <br /> requested from this office. <br /> The 21-foot beam is proposed to be at the roof level in the <br /> Southwest section of the building, and carries an 8-foot <br /> tributary width. The required size is (4 )-2"x12" and can <br /> be obtained by adding (2)-2"x12" each side of the 2"x4" <br /> cripple wall at the roof level . Post each end with (2)- <br /> 2"x4" each side to bearing. See enclosed detail . <br /> Respectfully submitted, <br /> STRUCTURAL DESIGN A5SOCIATES, INC. <br /> by: . ' � <br /> . ^ <br /> �: <br /> ;`./�� �i�� - ��,,-� �.e., <br /> i <br /> Kase Vanden Ende, P.E. <br /> president <br /> KVE/jme <br /> Enclosure <br /> u , . . , . . � � a _. . � <br />