Laserfiche WebLink
�� <br /> � <br /> � ENVIRONMENTAL HEALTH DIVISION <br /> � SNOHOMISH 3020 Rucker Avenue, Suite 104 <br /> HEALTH Everett,WA 98201-3900 <br /> DISTRICT 425.339.5250 FAX: 425.339.5254 <br /> Deaf/Hard of Hearing: 425.339.5252 (TTY) <br /> ' �`'�rc�(�'� �c���rn/� <br /> Dcccntbcr 2, 2009 j�, '- . � �1 �!(,/ <br /> G'cC i�^ 2009 . <br /> Gcair ��atkins -_ .i:ITY OF EVERET;�..... <br /> 2719 liewitt Ave. ��9ineeri���publir SPR,ices <br /> Gvcrctt, V�'A 98201 <br /> Subjcct: Proposed 13usy City Coffcc I louse, 2719 licwitt Avc, L'vcrct; <br /> Dcar Mr. Watkins: <br /> 1'our plans have bcen receivcd; howevcr thc plmis cannot bc approvcd us submittcd. 'I'hc following <br /> inlormalion is necdcd prior to liirther plan �evicw. <br /> I. No handwash sink is shown on the tloor plan for the front counter service �rea. A hundwash sink <br /> is requircd for this arca. The location of the handwash sin�: must be shown on the tloor plan. <br /> 2. Only one drainboard is shown on thc (loor plan for the three-compartmcnt sink. 1'hrec- <br /> compartmcnt sinks must have integral drninboards at each end. A d�ree-compartment sink with <br /> integral drainboards at cach end is required and must be shoan on the tloor plan. <br /> 3. No m.n;u(acturcr name and tnodel number was submitted for the tltree-compartmeni sink, and the <br /> brcwed coffcc maker. "I�he manufacturer name and model number for this equipment must be <br /> submitted. <br /> 4. All lood scrvice equipment must bc lisled by tlic National Sanitation Foundation (NSF) for its <br /> intended usc. 'fhc Unik cspresso machine and Unik grinder were not found in the current NSF or <br /> cyuivalcnt listings. 'I'his cquipment must bc replaced with NSr or equivalent lisled equipment or <br /> documcntation must hc submitted whicli demonstrates NSF equivalency. Manufacwrer names <br /> and mod�l numbers for replacemcnt equipmcnt or equipmcnt documentation must be submitted. <br /> Originally submittcd manuficturcr names and model numbcrs should be rccheckcd ro assure the <br /> inlormntion submittod is accuratc. <br /> i. No mop sinh is slio�vn on thc (loor plan. All food cstablislimcnts are required to have a mop sink. <br /> A mop sinl: is ra�uirod. ']'hc location of thc mop sink must bc shown on tlic (loor plan. <br /> G. "1 hc locatiun of Ihc cspresso machine, grindcr, and brewcd coffce makcr are not shown on the <br /> (loor pl:m. 'I'hc location of this cquipmcnt must be shown on the 11oor plan. <br /> 7. A sr.iting arca for customers is sho�vn on thc (loor plan. The current restroom acccss is lhrough <br /> the fi�od storage and dish�vashing arca. Customers are not permitted access to customer restrooms <br /> through thc food scr��icc, lood storagc arcas, or dishwashing arcas. Proper access to lhe resU�ooms <br /> by thc customcr that prcvcnts acccss through thc food storagc and dishwashing a��ca must be <br /> provided. 'I'he mcihod used to pre��cnt access to this area must be shown on the (loor plan. <br /> S. Submit a reviscd floor plan, drawn to scale, idcntifping all cquipment, showing Iccation of all <br /> cquipmcnt, plumbing fi�tures mid the like that inc:udes the required additional si���s an� <br /> infin•m:uiun. "l�he scalc of thr drawin,� must hc 1/4 inch equals I foot. <br /> � <br />