My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3120 HEWITT AVE 2018-01-02 MF Import
>
Address Records
>
HEWITT AVE
>
3120
>
3120 HEWITT AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2023 2:23:13 PM
Creation date
2/20/2017 9:09:56 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
3120
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />I <br />12 <br />82. <br />floor or landing not more than 1 inch below <br />1A the threshold is required on each side of an <br />exit door. Section 3303 (h). <br />83. <br />Doors should not project more than 7 inches in- <br />to the required corridor width when fully <br />opened or more than one half into the required <br />corridor width when in any position. Section <br />33D4(d)........................................................... <br />84. <br />Revolving (sliding) (overhead) doors are not per- <br />mitted as exit doors. Section 3303 (f). <br />85. <br />Exit doors should provide immediate access to <br />an approved means of egress. Section 3303 <br />(g). Exiting through another room does not <br />comply. <br />86. <br />Corridors should have a minimum width of 44 <br />Inches. Section 3304 (b). <br />87. <br />Corridors serving nonambulatory persons should <br />have an 8-foot minimum width. Section 3318 <br />(c). <br />88. <br />Dead end of corridors and exit balconies are <br />limited to 20 feet. Section 3304 (f). <br />89. <br />Walls and ceilings of corridors should be of one. <br />hour fire -resistive construction. Section 3304 <br />(g). An architectural section through the corri. <br />dor is necessary to determine how this is <br />accomplished. <br />90.1 <br />Exterior exit balconies cannot project into an <br />area where protected openings are required <br />due to location on property. Section 3304 (1). <br />.......................................................................... <br />91. <br />Interior openings into corridors should be pro. <br />1 <br />tected as specified in Section 3304 (h). <br />92. <br />Stairway .......................................... should have <br />a minimum width of .................... inches. Trim <br />and handrails should not project more than <br />3t/t Inches into the required width. Section <br />33l)5 (b). <br />93. <br />Risers on stairways should not exceed 71/z <br />inches and runs should not be less than 10 <br />inches. Section 3305 (c). <br />94. <br />Landings on stairways should have a dimension <br />In the direction of travel equal to the width of <br />the stairway but need not exceed 4 feet. Sec. <br />tion 3305 (f). " <br />95. <br />Landings should not be reduced in width more <br />than 3t/2 inches by a door when fully open. <br />Section 3305 (f). <br />96. <br />Basement portion of stairways should have an <br />approved barrier where continuous to upper <br />floors in an exit enclosure. Section 3305 (g). <br />97. IVertical <br />distances between stairway Iandin&6 are <br />limited to 12 feet. Section 3305 (h). <br />/ <br />98.1 <br />Handrails should be placed not less than 30 <br />inches nor more than 34 inches above the <br />tread. Section 3305 (1). Two handrails are re• <br />quired where stairways exceed 44 inches in <br />width. <br />99. <br />for stairs, balconies, and landings <br />should conform with Section 1714. Note that <br />1Guardrails <br />maximum clearance between intermediate rails <br />is 9 inches. <br />100. <br />Openings in exterior walls within 10 feet of <br />exterior stairways should be protected with <br />self -closing three -fourths hour fire -resistive as. <br />semblies. Section 3305 (k). <br />lot. <br />Enclosed usable space under interior stairways <br />should be protected on file enclosed side as <br />required for one -hour fire resistive eonstruc <br />tion. Section 3305 (1). <br />102. <br />Noncombustible exterior stairs are required. <br />Section 3305 (m). <br />13, <br />O <br />103. <br />Exterior stairs should not project into an area <br />(yards or courts) where wall openings must be <br />protected. Section 3305 (m). <br />104.' <br />One stairway should extend to the roof. Section <br />3305 (n). It must be in a smokeproof enclosure <br />in buildings over 75 feet in height. Section <br />3309 (b). <br />105:' <br />Six-foot 6-inch minimum headroom clearance for <br />stairways should be indicated on plans. Section <br />" <br />3305 (0). Note that this is from a plane tan• <br />gent to the stairway tread nosings. <br />106. <br />Ramp slopes should not exceed one foot in <br />.:.......... ................... feet. Section 3306 (c) (d). <br />107Y <br />Surface of ramps should be roughened or of a <br />nonslip material. Section 3306 (f). <br />10B. <br />Stairways should be enclosed as specified in <br />Section 3308. ' <br />(a) One (two) -hour fire -resistive walls are re- <br />- - <br />quired. <br />O Only exit doors are allowed to open into exit <br />enclosures. <br />(e) Doors should be labeled one (one -and -one- <br />half) -hour fire assemblies. <br />(d) Exit enclosures shou!d include a corridor on <br />the ground floor extending to the exterior. <br />Fire -resistive construction should be as re- <br />quired for the exit enclosure, including pro- <br />tected openings. Only exit doors are per- <br />mitted to open into the corridor. <br />(a) An approved barrier is required at the <br />ground floor to prevent people from acci- <br />dentally continuing to the lower level. <br />(f) Usable space is not allowed under the <br />stairs <br />............................................................... <br />109.1 <br />One exit from the building should be a smoke - <br />proof enclosure complying with Section 3309. <br />110. <br />Openings into exit courts less than 10 feet wide <br />should be protected with labeled 45-minute fire <br />assemblies. Section 3310 (d). Also see "exit <br />court" definition in Section 3301 (c). Openings <br />more than 10 feet above the court floor are <br />i_ <br />exempt. <br />111. <br />No openings other than required exits are per- <br />mitted in exit passageways. The passageways <br />should be of fire -resistive <br />.........................hour <br />construction. Section 3311 (a). <br />112.1 <br />Exit illumination and signs should be provided In <br />conformance with Section 3312. <br />113. <br />Aisle (cross aisle) in auditorium should have a <br />minimum width of ............................... Section <br />3313 (b). Section 3313 (e). <br />114. <br />Oanic hardware is required on exit doors serving <br />Group B Occupancies having an occupant load <br />of more than 100, Section 3316 (a). In lieu <br />of this, doors shall have no locks or latches. <br />115. <br />Mam and side exits in conformance with Sec- <br />tion 3315 are required for B-2 (1) Occupancies. <br />Section 3316 (a). <br />116.� <br />Corridors of Group C Occupancies should have a <br />width required by Section 3302 plus 2 feet, but <br />not less than 6 feet. Section 3317 (e). <br />117. <br />Each floor above or below the ground floor level <br />of Group C Occupancies should have no less <br />than two exit stairs. Section 3317 (g). <br />11B.' <br />Exit stairs serving an occupant load of more <br />than 100 in a Group C Occupancy should have <br />a minimum clear width of 5 feet. Section 3317 <br />(g)• <br />119.' <br />Every room with an occupant load exceeding <br />300 should have one of its exits into a separate <br />exit system. Section 3317 (b). <br />
The URL can be used to link to this page
Your browser does not support the video tag.