. <br />� <br />Lee Grocery - Exit Analysis <br />January 25, 19B5 ' <br />Page Two <br />� <br />West Building - Main Floor - 12,668 s.f. Occupant Load = 42, two exits <br />required. There are no legal exits from this floor. <br />1. Install new stair to same door to Hewitt required in N2 above. <br />2. Widen openings through center bearing wall to 44". No doors required. <br />3. Install new door in west wall to loading dock. <br />4. Install new door into the existing north exit foyer. <br />West n�ildinq - Upper Floor - 6,640 s.f. Occupant Load � 36, tvro exits <br />required. There are no legal exits from this floor. <br />l. Widen both stairs to required 44" minimum and add handrails both <br />sides. <br />2. Apply 1 layer of 5/8" Type "X" gypsum wallboard to the underside of <br />both stairs serving this floor. <br />3 requiredibyathescode butdis9notrfeltytoubeiaereasonableWrequest ats <br />this time. • <br />Eastrequired9 Theremare notlegal exits fromPthisLfloor.42� two exits <br />1. Construct new stairs to new door to the exterior approximately 5 ft. <br />north of the existing loading slip. <br />2. Construct new stairs to new door to the exterior north of the concrete <br />foundation for the old safe. <br />Eastrequire^. here are no legal2exits from�thistfloor. 42' two exits <br />1� andtinstallingelml/2 hourhratedrdoorePaProvide gap in conveyor�tonings <br />allow door to close. <br />