My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3926 HIGH ST 2018-01-02 MF Import
>
Address Records
>
HIGH ST
>
3926
>
3926 HIGH ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2022 12:49:56 PM
Creation date
2/20/2017 9:15:48 AM
Metadata
Fields
Template:
Address Document
Street Name
HIGH ST
Street Number
3926
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
102 /t 1 ' / <br />VC-21 Replace or repair, caulk and paint windows and doors as necessary. In rooms with <br />opcnable windows at least one must be operative. <br />VC-227 Install a 3/4" non-adjustable temperature and pressure relief valve on hot water tank <br />and a 3/4" discharge line to outside or to an interior drain. Rating of valve shall <br />not be greater than working pressure rating of water tank. <br />,C-23 / / / / (a) Replace all deteriorated rotted or damaged wood foundation and framing members, <br />including posts, plates, beams and joists in underfloor area, with sound material. <br />No wood to remain within 6" of ,round. <br />.;/ (b) Replace all skirting and other wood in contact with the ground with material <br />resistant to rot and infestation. Finish all exposed neN or repaired work to match <br />exterior. No wood to remain within 6" of ground. <br />VC-24 / / / / (a) Install new gutters, elbows and downspouts on maip building. Atool p r ._r and <br />wo coats of ,exterior paint: to match existing finisl\. ir,91(f/UV1 ti.iCYtS � <br />(b) Install elbows for downspouts and splash biocks to carry f wat r at least <br />r o <br />three feet away from foundation. <br />VC-25 / / Install plastic laminate or equal to kitchen counter top and back splash after first <br />replacing any damaged or rotted underlay. <br />VC-26 / / install at least four 8"x14" galvanized l:csdware c'.oth screened crawl space area vents <br />of i" mesh (one near each corner) to adequately vent crawl space area. <br />Note: Metal louvered nail on vents are not acceptable. <br />VC-27 / / install an acceptable vapor barrier ground cover over entire crawl space area. <br />VC-28 / / Crawl space shall be graded and sloped to prevent poAing of seepage water. install <br />drain the in gravel bed connected to suitable outfall to provide positive drainage <br />away from dwelling. Cover entire crawl space with acceptable vapor barrier. <br />VG-29 / / Install 1/8" screened hooded roof or 1/8" screened louveregable vents to provide <br />positive cross ventilation of attic space. <br />VC-30 / / Submit evidence that the leased / / gas furnace burner / / hot water tank has been <br />purchased from the utility company or ha.: been replaced with new equipment and is now <br />part of the realty. (Leased equipment not acceptable). <br />VC-31 / / Install new gas or electric _ gallon water heater with 3/4" non-adjustable tempera- <br />ture and pressure relief valve with discharge line to outside or interior drain. <br />Leased equipment not acceptable. <br />VC-32 / / Install a now forced air. wall, baseboard or other heating system adequat,: to heat all <br />finished rooms to 70 Fahrenheit. Submit heat loss calculations and installation plan <br />for approval prior to installation. Space or room heaters are not acceptable in <br />dwellings of this type. If electric heat is installed, adequate insulation and wiring <br />and service panel are required to meet minimum housing standards of authority having <br />jurisdiction. <br />VC-33/ Sand and refinish�l?lwood floors <br />JT` <br />Painted fir floors may be repainted. NOTE: The installation of carpeting and cushion <br />meeting 111-44b standards in these areas is an acceptable alternate method of satisfying <br />this condition. <br />VC-34 / %'/ Replace / / Repair garage door to function properly. <br />VC-35 / / / / (a) The FHA value is based on a lot size of <br />(b) Submit copy of correct legal description including lot dimensions. <br />VC-36 / / / / (a) Since a portion of the land offered as security is deemed to be ineligible <br />excess land, the Deed of Trust or Mortgage shall cover only the following <br />parcel which is eligible: <br />(b) The portion of land to be deleted consists of: <br />VC-37 / / Submit evidence from the local authority having jurisdiction that the subject property <br />has been connected to the % / public sanitary sewer system, / //-public water system. <br />'a <br />