Laserfiche WebLink
0 <br />INITIAL STORAGE VALUE FOR ITERATION PURPOSES: 549 <br />CU-FT <br />SINGLE ORIFICE RESTRICTOR: DIA= 1.49" <br />PERFORMANCE: <br />INFLOW TARGET -OUTFLOW <br />ACTUAL -OUTFLOW <br />PK-STAGE <br />STORAGE <br />DESIGN HYD: <br />.12 .06 <br />.06 <br />1.00 <br />107 <br />TEST HYD 1: <br />.06 .02 <br />.04 <br />.41 <br />30 <br />TEST HYD 2: <br />.12 .06 <br />.06 <br />1.00 <br />100 <br />TEST HYD 3: <br />.20 .13 <br />.20 <br />1.07 <br />110 <br />SPECIFY: D <br />- DOCUMENT, R - REVISE, <br />A - ADJUST ORIF, <br />E - ENLARGE, <br />S - STOP <br />E <br />ENLARGEMENT <br />OPTION: ALLOWS FOR INCREASING <br />STORAGE AT A <br />SPECIFIED <br />STAGE HEIGHT, TO <br />PROVIDE A FACTOR <br />OF SAFETY. <br />ENTER: STORAGE -INCREASE(), <br />STAGE -HEIGHT (ft) <br />130,1 <br />PERFORMANCE: <br />INFLOW TARGET -OUTFLOW ACTUAL -OUTFLOW <br />PK-STAGE <br />STORAGE <br />DESIGN HYD: <br />.12 <br />.06 <br />.04 <br />.52 <br />116 <br />TEST HYD 1: <br />.06 <br />.02 <br />.03 <br />.18 <br />30 <br />TEST HYD 2: <br />.12 <br />.06 <br />.04 <br />.52 <br />110 <br />TEST HYD 3: <br />.20 <br />.13 <br />.13 <br />1.03 <br />250 <br />SPECIFY: D - <br />DOCUMENT, R - <br />REVISE, A - ADJUST <br />ORIF, <br />E - ENLARGE, <br />S - STOP <br />D <br />PERFORMANCE: <br />DESIGN HYD: <br />TEST HYD 1: <br />TEST HYD 2: <br />TEST HYD 3: <br />STRUCTURE DATA <br />RISER -HEAD P <br />1.00 FT <br />INFLOW <br />TARGET -OUTFLOW <br />ACTUAL -OUTFLOW <br />PK-STAGE <br />STORAGE <br />.12 <br />.06 <br />.04 <br />.52 <br />116 <br />.06 <br />.02 <br />.03 <br />.18 <br />30 <br />.12 <br />.06 <br />.04 <br />.52 <br />110 <br />.20 <br />.13 <br />.13 <br />1.03 <br />250 <br />Mi,/)nn VM <br />R/D-POND (1.5:1 SIDE SLOPES) Toob 5 i2i �-j cm <br />OND-BOTTOM-AREA TOP-AREAlPl'F.B.) STOR-DEPTH <br />199.3 SQ-FT 415.0 SQ-FT 1.00 FT <br />PERMEABLE SURFACE: POND SIDES AND BOTTOM <br />SINGLE ORIFICE RESTRICTOR: DIA= 1.491, <br />ROUTING DATA: <br />STAGE(FT) <br />.00 <br />.10 <br />20 <br />.30 <br />.40 <br />.50 <br />.60 <br />.70 <br />.80 <br />.90 <br />1.00 <br />DISCHARGE(CFS) <br />.00 <br />.02 <br />.03 <br />.03 <br />.04 <br />.04 <br />.05 <br />.05 <br />.05 <br />.06 <br />.06 <br />STORAGE(CU-FT) <br />.0 <br />20.4 <br />41.7 <br />63.9 <br />87.1 <br />111.3 <br />136.4 <br />162.6 <br />189.7 <br />237.9 <br />247.2 <br />PERM-AREA(SQ-FT) <br />.0 <br />208.4 <br />217.6 <br />227.1 <br />236.7 <br />246.5 <br />256.4 <br />266.6 <br />276.9 <br />287.4 <br />298.1 <br />STORAGE -VOLUME <br />247 CU-FT <br />