Laserfiche WebLink
S.C.S. TYPE -IA RAINFALL DISTRIBUTION <br />ENTER: FREQ(YEAR), DURATION(HOUR), PRECIP(INCHES) <br />100 24.00 3.20 <br />••'•"•""""""«•" S.0 S. TYPE -IA DISTRIBUTION "•"•'•'"•'"•"""«•..« <br />"•"*""'"' 100-YEAR 24-HOUR STORM ""'" 3.20" TOTAL PRECIP. ••""*"""" <br />ENTER: A(PERV), CN(PERV), A(IMPERV), CN(IMPERV), TC FOR BASIN NO. 1 <br />.4 86.0 .0 98.0 32.2 <br />DATA PRINT-OUT: <br />AREA(ACRES) PERVIOUS IM: .RVIOUS TC(MINUTES) <br />A CN A CN <br />.4 4 86.0 .0 98.0 32.2 <br />PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) <br />.13 7.83 2710 <br />ENTER [d.][path]filename[ ext] FOR STORAGE OF COMPUTED HYDROGRAPH: <br />100.EX joc) yrc- <br />tiXt��tr�l�, <br />SPECIFY C - CONTINUE, N - NEWSTORM, P - PRINT, S - STOP <br />C <br />ENTER: A(PERV), CN(PERV), A(IMPERV), CN(INlPERV), TC FOR BASIN NO 2 <br />.2 90.0 .2 95.6 18.3 <br />DATA PRINT-OUT: <br />AREA(ACRES) PERVIOUS <br />A CN A CN <br />.4 2900 .295.6 <br />IMPERVIOUS TC(MINUTES) <br />18.3 <br />PEAK-Q(CFS) T-PEAK(HRS) VOL(CU-FT) <br />.20 7.83 3196 <br />ENTER [d:][path]filename[.ext] FOR STORAGE OF COMPUTED HYDROGRAPH: <br />100.DEV IuO `(Q. -r— t.cDF.F. y <br />SPECIFY: C - CONTINUE, N - NEWSTORNI, P - PRINT, S - STOP <br />S <br />Stop - Program terminated. <br />BEST Storm Drainage Report PERCO #96033 5/19/97 Page Ib <br />l/3 <br />