Laserfiche WebLink
C!1 <br />10. <br />11l <br />12. <br />13. <br />14.� <br />i <br />15. <br />16. <br />17. <br />18. <br />19. <br />i ;,�-- <br />( 20. <br />21. <br />22. <br />23. <br />P� LIC WORKS PERMIT COMMENT <br />Connect side sewer per City Standard #601. <br />Connect side sewer per City SlandaM #'s 601, 602, 604. <br />Connect all rooftop downspouts to tlie side sewer. <br />Connect rooflop downspouts lo the drainage system provided for this lot. <br />Rooftop runoff must be discharged lo a roof downspoul infiltration s��stem per Ciry of Everelt Storm <br />Manual 3-2.G.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />The coniractor must meel with the Public Works inspector lo discuss potential drainage rou;ing prior to <br />bec�inning the projecl. <br />Install erosion control measures as delermined by lhe Public Works inspector, such as silt fence, straw <br />bales, swales, or erosion blankets. <br />Install erosion conlrol measures per City of Everetl Standards for small parcels <br />Remove erosion control measures upon completion of the project prior to final approval o( the permit. <br />All excavaled material from (oundation, sidewalk and driveways shall be haided to an approved, <br />permitled site. No wasling ci malerial is allowed on this building bl. <br />No dirt, mud, rocks or debris to be tracked onto roadway. <br />No building materials to be slacked on sidewalks and sidewalks to be kept clean and open for <br />pedeslrian travel. <br />Adjust waler meter box 1" above sidewalk grade. <br />Remove and replace curb, guUer and sidewalk as per Cily of Everelt Slandard Plan JYs 305A & 30G on <br />this proposal's (rontage as directed by the Public Works Inspector (i.e. all unused driveways and any <br />broken or damac�ed area musl be replaced�. <br />Ins�all a Type I concrele driveway per Cily of Everett Standard t/307. <br />Pave drive�vay (rom the fronl property line out lo lhe streel paving. <br />Contacl lhe i-i�//.-/G � 2�< Water Districl for connecling provisions (or lhis building's water and <br />sewer services. <br />A catch basin as per Cily Standard Plan #402 with a gas trap per Standard Plan #410 is required for Ihe <br />parking area. <br />If a sewer pump syslein is to 6e inslalled, the pressure line must discharge into a private manhole, then <br />gravity (low across the public right-of-way. <br />A sprinkler system is required for this building in compliance with the requiremenls of NFDA Standards <br />13D. <br />FOR PUBUC WOFI<S INSPECTION, CALL RANDI' AT 425-339-7403 / CUFF AT 425-339-7404 <br />rr, :,�,;;a; <br />Y2 <br />