Laserfiche WebLink
� <br /> � <br /> � . <br /> �' � , <br /> May 16, 1980 <br /> , <br /> i <br /> , <br /> New Deal Tavern <br /> SNOHOMISH 1011 Hewitt <br /> Everett, Washington 98201 <br /> HEALTH <br /> DISTRICT Dear Sir: <br /> � Counhouse � <br /> � Everett.Washinglon 98201 Remodeling and building addition plans submitted 5 15 0 <br /> � AreaCode206 259-9440 have been reviewed. No specifications were submitted. <br /> ' Those plans are approved provided the following specifications <br /> and conditiona are added and made part of those plans : <br /> �I CLARISMYATT,IA.D.,M.P.N. 1. Dishwasher, •"B" , and compartment sink, "A", must have <br /> � """"°"„" indirect connection to sewer. Likewise, any other <br /> � oA��o � sTocAro�,�A.v.n. equipment in which food ia placed and from which waste <br /> water ia generated. <br /> �� 016TRICT MFNlE115 <br /> , LOUNIY 2, Handwash stations in kitchen and restrooms are to have <br /> � Snnnom�isn <br /> hand cleaner and towel dispensers conveniently nearby. <br /> GTIES AND TCNHS <br /> �rlm9ton <br /> a,�.•. 3. Exhaust systems (cooking surfaces and dishwasher must <br /> °'�m;�=: effectively remove excesa heat, steam, smoke, odora, <br /> ��,ao;, vapors. The exhaust hoods must have suitable filters <br /> ��^^����•"� and must meet fire codes. (Automatic, built-in fire <br /> ��a�. <br /> �••�s��.�^• extinguishing systems are required where grease laden <br /> �:�„"°,�� air is generated - deep grease fry, broiler, etc.) <br /> ' ��°"°` Suitable provision for entry of replacement air from <br /> „o����a,.,e,,.,. <br /> � s,'o''om`,� outside is required. (Don' t want replacement air <br /> �„�„000 <br /> , 5�,,,� coming through restroom windows . <br /> � ,vao�..� <br /> 4. Windowa of restrooms muat be effectively fly screened <br /> and back doors are to be self-closing and maintained <br /> closed or doorways fitted with self-closing, tight- <br /> fitting screen doors . <br /> 5. All practical effort is to be made to make building <br /> rodent proof, <br /> 6. Kitchen light fixtures are to provide good lumination <br /> on all work areas. Light fixture location is important <br /> along with the quanity of light provided. Light bulbs <br /> and tubea shall have protective coverings to prevent <br /> breakage and glass entering food. <br /> 7, All kitchen floors shall be smooth, durable and water <br /> impervious. Floor-wall junctures shall be coved and <br /> sealed for easy cleaning. The same applies for rest- <br /> room floors. <br /> 8. Kitchen walls are to be light colored, smooth, non- <br /> • absorbent, and easily cleaned. Restroom walls shall <br /> Ibe the same. <br /> I <br />