PllBL/� N/ORKS <br /> - June 19, 1995 <br /> DeI,eon CasWm Homes <br /> 1701 Orca View Lane <br /> Everdt WA 98203 <br /> �, p��; 7ohn Feilcer <br /> Job Address: 2113 E Grand <br /> plar► Check�:48506 <br /> Dear Dave: <br /> In rospo�se co your application for a construction permit, your plans have been <br /> eaam;ncd and you are advised that the issuance of a permit is being with held for the <br /> �n$ ug� ��ow, These comments address building issues only, additional <br /> revisions or additions may be required by other departments (such as Utilities, Plannin8 <br /> or Fire). A11 references refer to the 1991 Uniform BuildinB Code, as amended by the <br /> State of WashingWn and /or Washington State EnerBY Code 1994, lst Edidon, unless <br /> statcd otherwisc. <br /> 1, Floor plan does not show main floor framing. Show size and direction of floor <br /> joists. Show how opating at stairs is ftamed. <br /> 2. Stairs are re9uued t°be mi". 36" wide. <br /> 3, Below grade walls are raquired to be insulated co min. R-19 if insulatod on the <br /> interior. <br /> q, W�nding stairs may be used if the required width of nm is provided at a point <br /> not more than 12" from the side of the sqinvay where the treads are nairo�+'er, <br /> but in no case shall any widd► of run be less than 6" at any point. Show <br /> dimensions on plans. <br /> 5, Provide secdon and details of interior stairway showing: <br /> a. Maximum rise and minimum run. <br /> b, Minimum width <br /> c, Minimum headroom I <br /> d, Framing (stringer size, bracing, connections, footings) <br /> CITY OF EVERETT•3200 Cedar Street• Everett,WA 98201 • (206) 259-8802• Fax (206) 259•8859 � <br />