Laserfiche WebLink
t <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard N601. <br /> � Connect side sewer per CVty Standard#'s 601, 602, 604. <br /> C6.� Connect all rookop downspouts to the side sewer. <br /> 7. Connect rookop downspouts to the drainage system provided for this lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everetl Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide,2'deep and 25'long. See attachment for <br /> more details. <br /> 9. The contractor must meet with the Public Works Insp�ctor to discuss potential drainage routing prior to <br /> beginning the project. <br /> � Instali erosion control measures as determined by the Public Works inspector, such as silt fence, straw <br /> K� bales, swales, or erosion blankets. <br /> 11 Install erosion conlrol measures per City of Everett Standards for small parcels <br /> 12. Remove erosion control measures upon cumptetion of the projecl prior to final approval of the�ertnit. <br /> 13. All excavated material from foundation, sidewalk and driveways shall be hauled to an approveu, <br /> permitted site. No wasting of material is allowed on this building lot. <br /> 14.�� No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15. No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian travel. <br /> 16. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan#'s 305A 8 306 on <br /> this proposai's frontage as directed by the Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per City of Everett Standard#307. <br /> 19,,- Pave driveway from the front property line out to the street paving. <br /> 20. Contact the Water District for connecting provisions for this build!ng's water and <br /> sewer services. <br /> 21. A catch basin as per City Standard Plan#402 with a gas trap per Standard Plan dt410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, the pressure line must discharge into a private manhole, then <br /> gravity Flow across the public right-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> FOR PUBLIC WORKS INSPECTION, CALL RANDY AT 425-339-7403 I CLIFF AT 425-339-7404 <br /> PWComments <br /> �Z <br />