My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2601 E GRAND AVE 2016-01-01 MF Import
>
Address Records
>
E GRAND AVE
>
2601
>
2601 E GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 2:43:01 PM
Creation date
2/20/2017 2:42:49 PM
Metadata
Fields
Template:
Address Document
Street Name
E GRAND AVE
Street Number
2601
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S / �/ ( 1 <br /> \ <br /> , �/� � <br /> IanU;uy 28, 1998 <br /> Selro Develop. Inc. <br /> P O Box 1524 <br /> Snohomish WA 98291 <br /> RE: Owner. Selco <br /> Job Address: 26zx E Grand <br /> Plan Check N: 57635 <br /> Dear Mr. Selin: <br /> In response to your applicadon for a constiuction permit, your plans have bcen examined <br /> and you are advised that the issuance of a permit is being wittiheld for the reasons listed <br /> below. These comments address building issues only, additional rovisions or additions <br /> may be required by other depaztmenu (such as Utilities, Planning or Fire). All references <br /> refer to the 1994 Uniform Building Code, as amended by the State of Washington and/or <br /> Washington State Energy Code 1995 Edidon,unless stated otherwise. <br /> In order for the processing o[ your applicatlon W contlnue, it will be neces.�ary to <br /> provide t6e Building Dlvision wit6 two complete new sets ot drawin�s retlectlng the <br /> rnrrecdoes requested. <br /> I. Geotechnical investigation report is missing pages 6 and 7. <br /> 2. The 4 x 14 D.F. #1 beam at the overhead garage door appears inadequate, provide <br /> new beam siu species and grade. <br /> 3. Provide stair section showing: <br /> a. Handrail height and size <br /> b. Minimum iun, maximum rise <br /> c. :�finimum head room <br /> d. Fire resistive const. and firo blocking <br /> e. Framing (stringer size,bracing connections) <br /> f. Continuous handrail, return ends to wall <br /> 4. Gazage end panels are required to be min. 2'-8" wide (rough framing). Adjust <br /> dimensions as necessary. <br /> 5. Provide insulation baffle at each vent blcek. Baffles shall extend 6 inches <br /> veRically above the height of nonconpressed insulation, and 12 inches veRically <br /> above loose fill insulation. <br /> 6. Show that ceiling height for habitable raoms is a minimum of 7'-6". Show that <br /> ceiling height for laundry rooms, hallways, cocridors, and battuooms is a minimum <br /> of 7'-0". <br /> CIN OF EVERETT•3200 Cedar Street•Everett,WA 98201 •(425) 257-8800•Fax(425)257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.