1002 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
1002
>
1002 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 3:00:36 PM
Creation date
2/20/2017 3:00:08 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
1002
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
< . . <br /> Problems Identified <br /> 1) House is not protected from sewer surcharge event. <br /> Suggested Solution: Instali backwater valve in front yard area 7' deep. (See sketch). <br /> 2)The drain system installed at carpoR and inside French drain go to sewer, as does <br /> future balhroom slubs. <br /> Suggested Solution (A): Route drainage to sump pump that pumps to the front yard. <br /> Suggesled Solulion (B): Re-route drainage oulside of house to connect to side sewer <br /> downstream of proposed backwater valve. <br /> Suggested Solulion (C): Disconnect drainage from sewer syslem where adequate <br /> dislance from adjacent steep slopes exist. <br /> 3) Sewer line is flat inside basement. From north wall to side sewer. <br /> Solution: Trench basement and replace lp fix grade issue. <br /> Comments <br /> . All down spouts that are connecled to the side sewer could be disconnected and <br /> routed to splash blocks so that less flow is in the side sewer causing potential <br /> surcharge events.W here downspouts are routed to splash blocks the ground <br /> surface should be sloped away from the house. <br /> • Inslalling a grinder pump would provide increased protection from sewer backups <br /> beyond the protection a backwater valve can provide. <br /> Photos <br /> '� . .T, �i���.}� '� F� rt., ;t� <br /> ,e. M� l<�" <br /> L .1 5 � `� <br /> •... ` . - <br /> ,�r'�rr .c4', '.1 „� <br /> r . i.� .. i ,. <br /> . .�1r�� �t1 '���. . � �I <br /> .t '','�� 1 •','� r � <br /> • li/ !' � <br /> '�� .�• �'.� .... '�5 ' �� <br /> ,� ' . r � � �S•:�� +k� �. I� ..i <br /> �2' � • ' ��� • q .�, t+� ��7 �• ^i. <br /> � „ '� . , �� L.a" y•(`3ri..,7➢:' '� - :I. <br /> � �ir f.1 ✓f .,i 1 i , <br /> � 73r , 41 1 <br /> ,��i� 17' . Y., � �� <br /> �'A "_ - . � � :fl <br /> ■{�� ^ . •, � � _ „ <br /> � I <br /> d`_ ' .�,�`��, �[�.� -' ---' � ...•_i <br /> Backwater valve will be rnstalled under walkway <br /> G� <br /> I/ <br /> i <br />