My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1405 GRAND AVE 2018-01-02 MF Import
>
Address Records
>
GRAND AVE
>
1405
>
1405 GRAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2022 4:00:10 PM
Creation date
2/20/2017 4:15:11 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
1405
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � - <br /> ENG/NEERING / PUBLIC SERV/CES DEPARTMENT <br /> March l, 2006 <br /> Atefeh-Zarrin & HaRy Hrycenko <br /> 1512 Madison Way <br /> Lynnwood, WA 98037 <br /> Subject: Projcct: Hrycenko <br /> Job Address: ]405 Grand <br /> Plan Chcck No.: B0601-048 <br /> Dear Auti & Harry Ilrycenko: <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that the issuance of a permit is bcing withheld for the reasons listed below. These comments <br /> address building issues only. Additional revisions or additions may be required by other departments <br /> (such as Utilities, Planning or Fire). All references refer to the 2003 Intemational Residential Code, as <br /> amended by the State of Washington und/or Washington State Energy Code 2004 Edition, unless stated <br /> otherwise. <br /> In order for the �processing of your application to continue it will be necessary to <br /> provide the Building Division w�th two complete new sets of �irawings reflecting the <br /> corrections requested. <br /> 1. Provide minimum 36" lunding at the bottom of the stairs to the basement. Width of landing to <br /> be equal to the width of the stairs. <br /> 2. Concretc walls(along stairs) are required to bc insulated to minimum R-21 on the interior or <br /> R-10 on the exterior. Show all walls(in plan view) insulated. <br /> 3. Provide smoke alanns per R313 [RC. Show on plans per Section R313.1.1 IRC. <br /> 4. Providc landing at exterior door at new addition. <br /> Plcase prepare a response letter showing wl�ere eacft item in this correction letter is addressed on the plan <br /> set. <br /> Upon resubmittal of the drawings, your application u�ill be given priority and plan review will <br /> recommence. <br /> All rcyuired submittals shall be of sufficient detuil nnd contain sufficient infortnation to ensure that the <br /> proposed structure will be constructed in conpliance with all adopted codes. <br /> Sincerely, �� <br /> Jeff Hci an <br /> Devclopment Technician <br /> S:U V nJmy�WORD1HGil1.1AN,Nlm�Chcck No.80601-0i8.doc <br /> CITY OF EVERETT• 3200 Cedar Street• Everett,WA 98201 • (425) 257-BB00• Fax(425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.