Laserfiche WebLink
i <br /> ENG/NEER/NG/ PUBL/C 5E/�Y/Ct5 OEPARTiNENT <br /> .:i`��.�, 2oos <br /> Mr. Grcg Skclton <br /> GP Skclton, LLC <br /> 23G33 Woodway Park Road <br /> Edmonds,WA 98020 <br /> Projcct: New 7'ri-Plcx Pirc Suppression <br /> Job Address: 2106 Grand Avcnuc <br /> Plan Rcvicw No: K0803-002 <br /> Dear Mr. Skclton, <br /> In responsc�o your application for building construction pcmiit, tlic plans havc bccn _xamincd and you arc <br /> advised that a pennil cannot be issued until the following issucs are resolved. Pleasc provide a response Iettcr <br /> which shows�vhcre cach itcm in this co�rcction lcttc:is addressed on the plan sct. Por clarification,please <br /> cloud and idenlify any revisions lo A�c drawings in responsc to this Ictter. <br /> Construction: <br /> 1. Shcet I�I'-01 should bc rcvised to indicate a douUlc chcck dctector assembly on the vault dctail and on <br /> thc site plan, per City o;L'verett Standard 515 (attachcd). The DCDA sl�ould be dimensioned so that i� <br /> is locatcd na furihcr than 70 fcet from thc watcr main. Currcntly a I�CVA is sho�m on thc submittal. <br /> 2. 'I'hc domcstic�.vai�r:inc should Uc indicatcd on.hc sitc plan on shcct PP-Ol and conncct�d to thc main. <br /> �irc: <br /> 3. 7'lie 1�DC and PIV locations are lo Ue coordinated ���ith the I�irc Dcpartment. Contact Assistant Firc <br /> Marshal Rick Robinson to ti�scuss at 425-257-8123. <br /> Upon suUmissiou of two insert sets of re�•ised dra«•ings rc(lccting thc corrections requestcd,your application <br /> will Uc proccsscd. Applicablc codcs includc thc 200G Inicmational Buildir b Code(IBC),thc 2006 [nlcmational <br /> l�irc Code(ll�C),thc 200G ]nlem.tional Mechanical Code (IMC) and thc City oi I;verett Municipal Code, <br /> including Chapter 1 G.7G, Aulonmtic Pire Detection and Pire Suppression Systems. All codes refcrenced, as <br /> adopted Uy thc City of G��erctt, should indude current rcvisions by the Statc of Washingron. These comments <br /> address building issues only. Revisions or additions may be required Uy oQicr departments(such as Utilitics, <br /> I'lanning or Firc). <br /> All rcquircd submittais must be of sullicicnt detail and inforniatien to ensure that the proposed structurc will bc <br /> constructed in compliance with all adoptcd codes. You can rcach me directly to discuss this Ictter by c-mail at <br /> mhalcy(«)ci.c��crctt.�va.us or Uy phonc at 425-257-RS l3. <br /> Si� crcly, Ch��t: '�E� dy� f� lfliru� <br /> � �___.. <br /> i <br /> � � <br /> Cc: Bill I3ruce,Rick RoUinson,Gordon Witchcr,CO� <br /> / M g I�Icy, CAR13, Plans Exaniiner Gcnc Voloshenko, \'Vcstem Stutes Fire Protection <br /> CITY EVERETT • 3200 Cedar Slreet • Everett, WA 98201 • (425) 257-t3800 • Fax (425) 257-8856 <br />