f. <br /> . <br /> <. <br /> ENG/NEER/NG/ PUBL/C SrER///CE5 OEPA?TA/iEKT <br /> July 2, 2007 <br /> Mr. James McNcil <br /> 2415 Ruckcr Avenuc <br /> Gverctt, WA 987.01 <br /> RG: Owner. McNcil <br /> Job Address: 2106 Grand <br /> Plan Chcck No: I30706-0G3 <br /> Dcar Mr. McNcil: <br /> In response ro your application for a construction permit, }�our plans have been examined and <br /> you are advised that thc issuance of a permit is Uemg withheld for the reasons list� below. <br /> Thcse comments address building issucs only. Addrtional revisions, or additions, may be <br /> required by other departments (such as Utilities, Planning or Pirc). All references refer ro the <br /> 2003 International Bwldmg Codc, as amended Uy the State of Washington and adopted by the <br /> City of Gvcru and the Washington State Gnergy Codc, 2004 �dition, unless stated othcrw�se. <br /> In order for the processing of your application to continue, it will be necessary to provide <br /> the Building Division witli t�ro complete ne«� sets of drawings retlecting the corrections <br /> requcsted. <br /> 1. IBC 903.2.7 requires that the building b:; protectcd by an automatic sprinkler system. <br /> Por any non-protected door or window openings whatsoever on the north and south <br /> walls, [IIC 704.8.1 requires thc sprinkler system to be in accordance with IIIC <br /> 903.3.1.1. �vhich is an NPPA 13 System (not NPPA 13R). The intent should be <br /> includcd on thc plans. <br /> 2. Thc site plan indicates thc nortl� and south walls to Ue 5'-0" from the property lines. <br /> 'I'he tloor plans indicate some upper tloor walls to be 4'-0" front the property lines. <br /> IIIC 704.5 rcquires thcse walls to have a firc-resistance rating of one-hour that is rated <br /> for cxposurc Crom both sides. <br /> 3. Tl�e iloor/ceiling assemUlics are required to have a sound transmission class of not less <br /> than 50 and an impact insulation class oC not less than 50 in accordance widi IBC 1207. <br /> Please providc the assemUly construction detail and test agency identification number. <br /> 4. Thc stairway at the east end of thc building is required to be enclosed in accordance <br /> wiU� IBC 1019. The third floor storage room is not permittcd. Thc walls of this <br /> cnclosurc along with the other stairway and the elevator are required to Uc constructed <br /> as fire barriers with Gre-resistancc ratings of 2 hours. Thcse fire barriers are required <br /> to be continuous through concealed tloor/cciling spaces. The protection is required ro <br /> extend from thc top of the iloor she�thing to the undcrside of the tloor sheathing above <br /> (See enclosed I13C 706.4 commentary). All doors into the exit stainvay enclosures are <br /> required to iiave a fire protection rating of 1 �/z hours in acwrdance with IBC 715.3. <br /> CITY OF EVERET7 • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 <br /> 'Iv <br /> PIP'1'I��I:V�Il.•.11111811i o^.i�.�l]I,*.(IN1N1�� <br />