My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2409 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
2409
>
2409 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2017 7:10:41 PM
Creation date
2/20/2017 7:10:25 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2409
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> I <br /> i <br />� a <br /> _ <br /> I <br /> December 3, 1975 <br /> d;e r'v�ynr,�e: <br /> CITV OI' <br /> everett <br /> Richard A. Almvig ��.. ��•« • _�_��>.:, <br /> 871?. River Crest [VEN[lT. WAS!IINciON <br /> Everett, Washin ton 98203 '���� <br /> � incrccna�+ o[rnnrr+v+r <br /> Reference: Apartment IIuilding <br /> 2909 Grand Avenue <br /> Type of Construction V-N <br /> Oc:cupancy li <br /> Fi.re Zone 3 <br /> Occupant Load 48 <br /> Plan Checic No. 75-433 <br /> Dcar Mr. Almvig: <br /> The plans for the above referenced project have been reviewed <br /> and the follotaing corrections are required to comply with th�: <br /> Unform IIuilding Code. <br /> 1. The huilding i.s limited to 2 stories as a Type V-N � <br /> stucture. Section 507 and Table No. 5-D . � <br /> i <br /> 2. NonaUsorbent finish and backing for toilet room I <br /> walls and floor should coniorm �vith Section 1711 (aj . <br /> 3. A Group G Occupancy more than two stories in height <br /> or having more than 3000 square feet aUove the first <br /> story should be of ona-hour fire-resistive construc- <br /> tion throughout. . SecL-ion 1302 (b) . � <br /> 4 . Two exits are reauired front the areas below as � <br /> specified in Se�tion 3302 (a) . Second and third <br /> floors. <br /> 5. �xits should have a minimum separation of one-half <br /> the maximum overall diagonal oi Che building or <br /> area served. Section 3302 (c) . ' <br /> G. Handrails should be placed not less than 30 inches <br /> nor more than 34 inches above the tread. Section <br /> 3305 (i) . Two handrails are required whcre stairways <br /> exceed 4A inches in width. <br /> 7 . Guardrails for stairs , balconies, and landings shou.ld <br /> conform with Section 1719 . Not•e th,it maximmn clear- <br /> ance between intcrmediate rai_ls is 9 inches. <br />
The URL can be used to link to this page
Your browser does not support the video tag.