Laserfiche WebLink
.. . -.- <br /> ��� c � <br /> Y <br /> �vecic woRxs <br /> .�:.:: <br /> Plan Check � B 49343 <br /> September 1, 1995 <br /> Page 2 <br /> �I� 7. Stairs must have a flush or angled nosing. Sec. 1106.9.3. Treads must be 10 <br /> inches minimom. Sec. 1006.3. <br /> ��� 8. Please provide ezit signage and illumination per sec. 1012 and ]013. <br /> �/9. All units must be type B accessible units. One bathroom within each unit must <br /> have a 3'-0" wide door and a 30" z 48" unobstructed floor space in front of the <br /> tub. (units B & C main bathroom dimensions don't work and toilet encroaches <br /> on floor space). Sec. 1106.27.1. <br /> ✓10. Roof drains require equal size overflow drains or scuppers. Sec. 1506.3. Roof <br /> drains must be tighdined to the storm sewer. <br /> ✓11. Please provide details and calculations for attic vendladon. Sec. 1505.3. <br /> �12. Attic access is required. Sec. 1505.1. <br /> In order for the processing of your applicadon to condnue, it will be necessary to <br /> provide the Building Division with two comp;ete new sets of drawings reflecting the <br /> corrections requested. <br /> Upon resubmittal of the drawings, your applicaGon will be given prioriry and plan <br /> review will recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to <br /> ensure that the proposed structure will be constructed in compliance with all adopted <br /> codes. <br /> Sincere , <br /> fr S. Mc all <br /> Associate Engineer/Building <br /> 1M:jd:pc49143 <br /> CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206)259-8800 • Fax (206) 259-8856 �°d <br />