Laserfiche WebLink
GENERAL PLAN CORRECTION LIST <br />1losed on 1.473 rdition of the Uniform Building Code <br />Own er..5at. 1-txz ats_%T.K,teTja l.. <br />Job Mlrass . z. i 2...... ta!zg� D.............................. <br />.............................. <br />^I <br />Total /'Ip;,able Floor Area ...-*x. .............. Sq. rt. <br />13254forincraase <br />�__r.�.F..� ....3...............1_.a: ? 4......................... <br />..........................:. <br />_._....___.................... _......... 1,...T ..1.a.............. :.......... <br />"+ 'COMMENTS Of? ASSUMPTIONS - <br />Plan C11,00%........................... <br />Use .PPP tiTJ-��,t_r.T 5............................................ <br />Typo of Occupancy <br />Construction.Z-.1-k....... Classification ....N.............. <br />Fire Zone No......3............ Stories z....t...&ASC,ftTat: <br />rioor Arda: <br />r(oor .................................. Sq. Ft. <br />Floor (Total) .....t,..`_1..1?..... ,...... 0 f4.................. Sq. Ft. <br />Occupant Load J. t�....tA.... <br />Cnrrc':ess chricf:ed below are to be made on plans before permit is issued. <br />- The et;::vai of plans and specifications does not permit The violeGon of any section of the. Dui Jing Code, o: other City Ordinance or <br />Slctc UR. ' <br />�_ GFIiEIi/cL <br />1. <br />Vzluanon should be <br />P. <br />.how job address on plans. <br />.3. <br />Give came of person rosponsihlc for plans. <br />4. <br />Submit fully dimensioned plot plan. <br />1 <br />Give all dimensions on plot plan. <br />ARM LIMITATIONS AND GENFRAI. <br />• OCCUPANCY IMQUIREMENIS <br />6. <br />Grrtd '1ICPafioa5 should he She•an at. corners <br />of file building and at chant,es in Ground slope. <br />The ground elevations should be taken at the <br />lowest pond between the exterior will and a <br />point 5 feet out or at the ptopeuy line, if <br />clnscr. 14hcre the exterior wall is peralle! to and <br />vrithur 5 feet of a public sidewalk, Mley, or <br />olhrr public way, the ground elevations should <br />he the eievalion of the public way. The number <br />of stories in this bui:ding cannot be dcicrmined <br />wdil this data is furnished. <br />7, <br />llle total floor area is limited to ........................ <br />square feet. Sections 505 and 505. <br />S. <br />Unobstructed yatdc of .................... feel should <br />be maintained on .................................... sides <br />of the building for area Purposes. Section 506. <br />B. <br />Provide details to show that .............................. <br />•hour area separation malls should comply with <br />!'cclion 505 (c), <br />(a) Ll.tt•nd vertically front the. Inundation to a <br />poinl•30 inches ahnvr the roof. <br />(b) Total width of all openings limited to 25 per. <br />cent of the wall length in the story under <br />consider a lied. <br />(c) All openings protected with fire assemblies <br />having a firc•resislive raling of one•and•otte- <br />half (three) hours. <br />(d) Ducts t!natgh area separation wails should <br />be ave'raed. If alicv:ed, fire dampers on each <br />side of the wall are required. Section <br />3D.102, U.B.C. Standards. <br />10. A fire-resisfire occupancy separation in conform - <br />once erftlt Table No. 5•D and Section 503 is <br />required hctvmen the <br />......... _............................. (...........:hours) <br />........ _......................:.................---...hours) <br />..........._.._...................:.......... (..::...:.._hours) <br />11. Norimnlal occuponcy separations should be up <br />potted w•;at a structural system having equiva- <br />tent firmer caislive protection. Section !303 (b). <br />12. The buildinC is limited to ........................ stories <br />(.........._...... feet in Imcigiit) os a Type .............. <br />structure_ Section 507 and 1 able No. 5-D. <br />I� 13. A room fn ehich a water closet is Inwled should <br />be separated from fond preparation or storage <br />trouts by +. tight-litling door. <br />TVIlr OF (:LNSTRUCTIoN <br />14 Type V (111-14) OVdJ) buildings are tint permitted <br />Ill Ilrr. 7on� IJo. 1. Section 1G02 0). <br />15. Roof covcrioPs should he file rrlatdanl. Section <br />1704. Dclans or speUlie:d i ons <br />comptyint; trilh Sechon 1203 (a% are, required. <br />CI. .d tjn 1 nr r. Ott-M <br />