My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2423 GRAND AVE 2018-01-02 MF Import
>
Address Records
>
GRAND AVE
>
2423
>
2423 GRAND AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2022 7:21:05 AM
Creation date
2/20/2017 7:19:36 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2423
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M <br />f <br />I?j. <br />17hen three or More exits are required, no "lore <br />than hvo required ends should en( into the <br />saint- exit system. Section 3317 (It). <br />Mr <br />No point in a room in a building should br, more <br />than 75 feet to an exit corridor, enclost:cl stair• <br />way or cxlotior of the building. Section 3317' <br />ram), <br />)22. <br />Exiling through adjoining toonts should comply <br />with Section 3317 (d). <br />123. <br />Panic hardware is required oil exit doors serving <br />rooms containing more than 100 occupants <br />and in corridors of Group C Occupancies. Sec. <br />_- <br />Pion 3317 (j). <br />12, <br />t.vely loom in a Group D Occupancy should have <br />access to at least Iwo legal means of egress. <br />Section 3318 (a). <br />12 Doors <br />from bedrooms and wards of Group D <br />Occuimocius and all exit openings where "oil• <br />ambulatory patients are housed should have a <br />minimum clear width of 44 inches. No pro• <br />jections in this width are alcoved. Section 3318 <br />v <br />(b). <br />12v. <br />Panic hardware is required on exit doors serving <br />more than 50 occupants in Group D Occupan- <br />cies unless there is no latch or lock. Section <br />3319 (I). <br />I1.0011, floor CONSTRUCTION, C0VERMC, <br />SKYLIGHTS, ROOT STRUCTURES <br />T <br />121. <br />The space bcix•een word floor construction and <br />a suspcitac i ceiling l,•rbrn should be divided <br />into areas not exceeding )000 square feet. <br />Section 2517 (s- . <br />M. <br />Attics " combustible material shuuld he divided <br />Into areas tlnl exceeding 3000 (900D) squale <br />fact. Section 3205 (b). <br />r� <br />12?. <br />Roof dlainage should Pe conducted under the <br />Public sidewalk. Section 3207 (a). <br />1��. <br />~Oveillow drains having the same size as toot <br />drains and on independent stain lines arc to. <br />Qt1hod. In lieu of this, ewl•rflOw scuppers three <br />times the size of roof dr;:ins should be installed <br />In Parapct walis. Overflow system should have <br />Inlets located 2 inches above the tow points <br />MM32JI. <br />of the roof. Section 3207 (c). <br />The aggregate area of <br />penthouses and other rrof <br />structures cannot exceed 33 I percent of the <br />supporting roof atea. Section 3601 (b). <br />• 11RE•EXTINGUISHING SYSTEM <br />132. <br />An approved automatic lily-extioCuishing system <br />infile ............................................ Is requited. <br />S,clion 3802 (b). This includes blind spaces <br />enclosed wholly or pa•tly by combustible con• <br />shuclion. <br />I- . <br />j Dry standpipes are required in buildings four or <br />1 more stories in height. Section 3803. <br />73:.IN'el <br />slandpipes are required as specified in Sec. <br />^ <br />lion X;0.1. <br />135.E <br />Colilbinalion slandpipes aw required in build• <br />ones exeoding 150 feet in height. Section 3805 <br />135. Buildings six slotics or nlnro in Iteigld should be <br />provided with nil less than one slandpipa dur• <br />i <br />intr. construction. Seclinn SIi00 (b). . <br />lire rxtie!;uislung system Plans should be still• <br />milled to you In detnluune eotupliauco with <br />npplicablo hudli"g, Phmlhioll, and fire codes. <br />• 1111111LACES AND C111rdNEYS <br />138. Chinutcys should comply with Sections 3703 <br />and 3704. <br />130. f ireplares and barbecues should comply will% <br />Section 3707. <br />• rINISH WORT( <br />140. <br />The interior wall and ceiling finishes should be <br />specilicd and eonq:ly with Table No, 42-B and <br />Section 4203. <br />1W <br />Gypsum wallboald (interior IaUI and plastor) <br />cannot be installed on wealherexposed sur• <br />faces. Sections 4705, 171). See Section 42.4 <br />for definiliou of weather cyposed surface. <br />)42. <br />Skylights should comply with Chapter 34. Plastic <br />skylighls are allowed only Under the conditions <br />specilicd in Section 5205. <br />)43. <br />Glass and glazing should comply with Chapter <br />54. Typo and thickness of glass shuuld be <br />'specified. <br />144. <br />Glass end glazing in hazardous locations should <br />comply v.ith Section 5406. <br />STRUCTURAL. <br />)45. <br />Special inspection in conformance with Section <br />305 is required Inc the following work: <br />(a) "hucturof concrete where the design Is <br />based on ;.n ultimate compressive strength <br />in excess of 2000 pounds por square inch. <br />(b) All weldini: except where done in the shop <br />of an :approved fabricator. <br />(c) Itratallailon of Mini slrerlEth bolls. <br />(d) I'reslressing %•rork. ' <br />(e) Masonry wort: required by Chapter 24. <br />MCI. <br />SoiLdrss!fiealion in conformance with fable I'a. <br />28 11 and ............................ pounds per square <br />foot soil beating value used in design should <br />be specified on plans. Section 2905 (a). <br />147. <br />The inundation investigation report mentioned in <br />Plans was not included to data for.vor.!ed to us. <br />.It shotdd be submitted for revie•.v. <br />148. <br />All masonry or concrete elements resisting seis• <br />' <br />nlic forces should qualify as reinforced cla• <br />meals. Section 231.1 (k) 3. <br />149. <br />Precast concroic wail panels are limited to an <br />• <br />h/t ratio of 36 (25). Section 2616 (c). <br />150. <br />Wood tnembers may support loads from ma- <br />sonry or eancreto only under the conditions <br />specified in Section 2516 (a). <br />151. <br />Structural calculations should be submitted to <br />luslify Idle adequacy of the structural system <br />1n resisting seismic and wind leads, and sup• <br />polling dear) and live loads. This includes <br />foundations. <br />152. <br />Justifying calculations and detail:: should be pro• <br />videofor............................................................ ' <br />........................................... <br />]53. <br />Roofs shall be designed for snow loads of <br />...................... pounds per square foot. Section <br />2305 <br />' <br />154 <br />him of should Ila designed for uplift wined pros• <br />sties with (life considrntion for lateral support <br />of compression Ilangf:s of flexural mrulbcts. <br />15!i. <br />hoar load should citimider a 20-pound par <br />square lout parliliun load. Scclion 2:102 (b).+ <br />]LG. <br />Id:uquers should be designed Int a r,Dglound per <br />sgtialc ((lot live load.'1able No. 23-A. <br />
The URL can be used to link to this page
Your browser does not support the video tag.