Laserfiche WebLink
Janu�ry 17� 15G6 <br />'dr Lyl� i�eni <br />�elective Properties <br />2737 Hoy{ <br />Evorett� 1'+nshington <br />n�: r �il l ur,md �5�,. <br />Dear Lyle: <br />An electric.�l inspection was made at 2511 Grand and the fo,lowinp <br />corrections need to be ma�fe: <br />Two outlets are needed <br />room or near the are�. <br />pull down li�ht. <br />in the dining room �i {he east end of the <br />A n�{.>1 bex is n�edec for connection of' the <br />�ne outlet i, ncrded �n the n:.rth wall ��� the dovin s{nirs front <br />bedraom. <br />The ouilets in ihe kitchen and utility must be prounded ^nd put on <br />an appliance circuit. <br />The biggest problem in this hous� is an inadequete service ard panol. <br />Circuits are doubled up on terminal screws enc� ��-�mp fuses installed <br />to hold the circuit. Thc dry�r is on the s�;r: ,:i;cuiF as the r2n�e <br />which is using a lar�,er func :hnn pc�rmi.ted for i dryer. Side panels <br />ere used with fused neutrals. They should be combined '�nd insttlled <br />in one rmin pnnel which would correct the problems �vith the service. <br />A feN open connections in the ba,ement ahould be correctod; the up- <br />siaire ligh{ fixtures are broken or inoperative and should be fixed. <br />Most of theso corrections� except for ihe service, erc of z sm.ill <br />n�ture. <br />Yours truly <br />L, J. Dougherty <br />Electria3l Inspector <br />LJD:rm <br />