My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3010 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
3010
>
3010 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2017 2:18:36 PM
Creation date
2/20/2017 8:27:29 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
3010
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
105
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br />� <br />16. Ezterior (court) walls within .................... feet ot <br />lines shouid be of ...............: hour construction. <br />� Section .................... 03 (a). <br />17. Openin�;s in ezterior (court) walls within ............ <br />lect oi pro�crty lines sliould �c protected with <br />lhree•fourtlis�hour fire assem6lics. Seclion � <br />� . .................... 03 (b). <br />78. Usable space under thc first floor extept in <br />Group I(J) Occupancies sl�ould be enclosed <br />as required in Seciion 1703_ <br />I9. Fire•resistive construction for structural frame <br />elements in the ezterior walls should comply <br />. with Foolnotc No. 1 of Table No. 17�A and <br />Section ......................... See Section 1702 for <br />ciarification. <br />I20.`jBui�ding paper should be applied to rzterior <br />��wails as specified in Section 1707 (a). <br />21.� Enctosures for floor openings should comply <br />with Tabie No. 17•A, Section 1706. Details <br />should ctcarly indicate this. <br />22.�IStructural members carrying masonry or eon• <br />crete wal�s in buildings over one story in height <br />shouid be protected with minimum one�hour <br />fire protection. Section 1708. <br />23.'jNonabsorbent finish and backin� for toilet room <br />Iwalls and iloor shouid eonform with Settion <br />1711 (a). <br />24.'IShower stall N•alls should be finished with a <br />hard, nonabsor6ent surtacc to a height of 6 <br />teet. Section 1711 (b). <br />25.' Doors and paneis of shower and batlilub en• <br />closure should comply with Section 1711 (e) <br />to (C)• <br />26.' Parapet walls not less than ................ inches in <br />I,heiylit are required. Section 1709. <br />27. Eave overhangs and similar architecluret pro- <br />jections should compiy with Section 7710. <br />26.�� Projections beyond the ezterior wall shouid con• <br />. form with the Icast �estriUivc of the followin�: <br />(a) A point one4hird the distance to thc proper <br />, ty linc from an extcrior wall. Section 504 <br />(b). <br />(b) A point one�third tlic distancc from an as• <br />sumed vertical plane localed where fire- <br />resistive protection of openin�s is first ra <br />quired due to locatio� of property. Section <br />. 50.4 (b). <br />29.� Envdope ccilings shoulA satisly thc followins <br />conditions [Seetion 43('i (b) 6.1: <br />(a) Should nol bc useJ lo proviAc lirc protec <br />tion bcam . nd girdcrs supportinp more than <br />onc iioor. <br />(b) Columns should bc individuaily firc pro• <br />tected. <br />(t) Duct and outlet epenings arc liiniled to ]00 <br />square inches in cach ]00 squarc fcet ol <br />tcilin� orca anc should bc p�otecled with <br />approved I:m dampr.rs. <br />(d) EleUrical outlet Bozes shouW be of stect <br />. nd not grcatcr Ihan 1G square inches m <br />I area. <br />30.°IGypsum Goard ceilin�s in conjunction with lire• <br />re5istivc nssemblics Should bc suppOrted at <br />inlervals nol exceedin� ]G inches. Item 27, <br />Tablc No. A3�C. <br />31 <br />32. <br />Wood stripping or suspendcd wood systcros (or <br />gypsum board eeilings shoulJ bc not less than <br />2•ineh nominal thickness. Scction A704 (b). . <br />[Seclion 4703 (b) lor wall ;tripping.] � <br />Final partition layou[s and dclails 51muld hc sub• <br />miked prior to installation to justify compli� <br />ance with occupancy, fire�resistivq struclurai, <br />and ezit requirements. <br />33.� Justifyin� test Aata in conformance wilh Section <br />106 or an IC00 research recommentlalion is <br />requiredfor ....................................................... <br />34." �Rooms in which rubbish (linen) chutes terminote <br />should be separatetl from thc remainder of the <br />� building with a one•hour occupancy separation. <br />Seclion llOG (c). <br />35� Openings into ru6bish and linen cliutes should <br />not 6e located in requireA ezit corridors or <br />stairways. Section 1706 (c). <br />SPECIAL OCCUPANCY REQUIREMEN75 <br />Group B <br />36. B�3 Occupancics shoulA be of onc�hour firc• <br />resistive construction il located in a ba:ement <br />or above.lhe first story. Section 702 (b). <br />37. 8•2 Occupancies vrith an occupant loatl of 1C00 <br />or more stiould bc in Type I, 11, III one•hour. III <br />Heavy Timber or IV one�hour buildings. Tlie <br />assembty room should not be in a basement <br />if it contains this high occupant load. Setlion <br />702 (b). <br />36.. The main entrance should lront dimctly upon or <br />have'a 20•foo: wide access to a public way at <br />Icast 20 feet in widih. Section 703. <br />39. Light and ventilation should comp�y with Section <br />705. <br />40. A One�Hour Fire�Resistive Occupancy Separalion <br />Is req�;red bclween the builer or centrai hcat• <br />Ing piant and the rest of thc buildin�. Sttlion <br />708. <br />41. Ezterior opei�ings for rooms containing a boiler <br />or cenVal heating plant should be prolected <br />wilh tlircc•fourths�liour lirc�resistivc assemblies <br />that arc tixed, automatic, or scl6dosing if Io• <br />cated below openinGs in another story or if Icss <br />than 10 fcet lrcm othcr doors or windows in <br />the samc building. Section 708. <br />Group C <br />I 42 I Atmosphcric separations shoWd campiy with <br />Seclion 802 (b). <br />' A3. Usc ot rooms should be clarilicd. Nolc th�t <br />rooms in Divisions 1 and 2 Occu�ancies ��sed <br />for day wre purposes and rooms uscA for <br />kindergarfen, firsl, or second �r, de pupils . ntl <br />Division 3 Occup�ncies cannot be lowted <br />above tl�e tirst story. Seclion 802 (c). <br />44. Special hazarA rooms 511au�d bc separaled fronl <br />olhcr porlions uf Ihc buildin�, by not Icss tlmn <br />a One�Hmir firediesislive Uccupancy separa• <br />tion. Section F302 (d). <br />45. Onc rcquiicd cait shouid front dimcUy upon, or <br />Imvc n 20�l001 widc acccss to, a puBlic way at <br />Icnxl 20 (cet in widlli. Sedion Y03 (a), <br />46. Sinilary ficiiilics shOUld bc providcd in accord� <br />ancc with Sc�:lion QOS. <br />47. 1 i�;ht , nd •icntilalion shoulJ compty with Seclion <br />Fi05. <br />0 <br />d= <br />
The URL can be used to link to this page
Your browser does not support the video tag.