My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3207 GRAND AVE 2016-01-01 MF Import
>
Address Records
>
GRAND AVE
>
3207
>
3207 GRAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2017 8:11:09 PM
Creation date
2/20/2017 8:38:26 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
3207
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF EVERETT <br />BUILDING DEPARTDiEVT <br />PLAN CORRECTION SHEET <br />DATE Marcn 20, 1986 , <br />01VNER <br />CONTRACTOR o'Connor a oehler <br />DE�iGNER <br />JOB SITE A.DDRESS � <br />-'r^_vT.,rand Avenue <br />TYPE OF CO�:STRUCT.O� <br />USE <br />USE ZONING <br />FIRE ZONE <br />OCCUPANCY GROUP <br />OCCUPANT LOAD <br />PLAN CHECK NO. 46/16233 <br />In response to your application for a permit, youi• plans and spec�-.fications <br />have been exanined and you are advised that the issuance of a germit is <br />withheld f��r the reasons hereinafter set forth. NOTL• CAREFULLY: Answer <br />questions and make explanations b correctin ori inal lans, and new <br />p73ns must be submitted to �,ie Buil ing Inspection Department. (This sheet <br />must be returned with original plans and specifications or they will be <br />filed as n^w business.) <br />Item No. <br />✓ 1. <br />'�2 . <br />''3. <br />�4 . <br />,j 5. <br />.� 6. <br />✓7. <br />� 8. <br />/ 9. <br />10. <br />✓ 11. <br />1��12. <br />UNIFOFLN BUILDING CODE 198� EDITION CODE SEC. <br />Openings in guardrails are limited to 6". <br />Floor-ceiling assembly and walls between units to comply <br />with sound insulation values. <br />Shower/tub recesses to be finished. <br />Verify winbow headers are 4" x 8". <br />ReinfoccinS shown in Details 1 and 2 to be #4 at 16" o.c. <br />each w:iy with vertical bars located 2" from outside face. <br />All footinqs to be 8" x 16". <br />All anchor bolts to be sFaced at 48" o.c. <br />Raise bottom of isolated footing shown in Detail 3. It <br />undermines the perimeter footing. <br />Reinforcing in Detail 6 to be #4 @ 24" o.c. each way. <br />4" x 6" floor beam is greatly overstressed. Suggest <br />continuous footing with 2-#9 and pony wall. <br />Provide exhaust fan in laundry room. <br />Provide additional informatio for stair construction; <br />both wood and conr_rete. <br />�, <br />J ck E. Frets <br />1711 <br />Appendix <br />Chapter 35 <br />510 (b) <br />Page 1 of 1 <br />