My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4711 GREELY ST 2018-01-02 MF Import
>
Address Records
>
GREELY ST
>
4711
>
4711 GREELY ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 2:02:41 PM
Creation date
2/20/2017 10:12:37 PM
Metadata
Fields
Template:
Address Document
Street Name
GREELY ST
Street Number
4711
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Address or site ID: <br />FINALS PHASE 1997 WSEC Residential Checklist page 4 <br />Co liance Required ✓ <br />Inspection Approved J <br />VP <br />.30. Envelope floors shall be insulated without compression with support 5 24" o.c. to: R- <br />31. Non -vaulted, attic ceilings shall be insulated without compression to: R- <br />IF. <br />32. Doors shall meet U-values as per the Door Schedule & Prescriptive Option (or as calculated per Chap. <br />4 or 5 Qualification . <br />33. Exposed foam insulation shall comply as follows (5.502.2.4.7): <br />Protected with metal or plastic flashing, or other suitable material that expands below grade. <br />b insulation is a roved for sub ade, exterior use and property installed. <br />34. Airflow between fresh air ports and whole -house fan ensured by undercut doors/grilles. <br />Q O <br />35. Loosefill insulation okay if (S.502.1.4.5): <br />a) Maximum ceiling slope not >3 in 12. <br />b z 30" clearance distance from to of bottom chord to underside of <br />roof sheathingat roof ridge, <br />36. 6 mil black polyethylene ground cover shall be lapped 12" at joints & extend to foundation wall. <br />Q <br />O <br />37. Clearances shall meet listed minimums between insulation and (S 502.4.3): <br />Q <br />a Chimney b Non -IC rated recessed lights: 1 2" to combustibles, 3" to insulation <br />38. Attic hatch shall be insulated to required ceiling R-value and weatherstripped (5.502.1.4.4). <br />Q <br />O <br />39. Attic access shall have wood dam or equivalent to retain loose fill insulation in attic (5.502.1.4.4). <br />O <br />40. All exterior doors (except 20 minute doors) shall be weatherstripped (5.502.4.3). <br />O <br />41. Service hot & cold water piping in unconditioned spaces shall be insulated to R-3 (5.503.11). <br />Q <br />O <br />42. Service recirculating not water piping in unconditioned spaces shall be insulated to Table 5-12. <br />Q <br />O <br />43. Heat pump thermostat shall have programmable capability (S. 51&3.5). <br />44. Thermostat provided for each HVAC system with range of 55-75° F (heating) (S 503.8.1.1). <br />Q <br />O <br />45. Readily accessible, automatic or manual means provided to restrict or shut-off Heating input to each <br />zone duringperiods not uirin heat S 503.8.3.1). <br />O <br />46. Mechanical ventilation system shall have proper timers, and/or switches (VIAQ, S 302.3). <br />O <br />47. Mechanical ventilation ducts shall have R4 insulation in unconditioned spaces (VIAQ< S. 302.5). <br />O <br />48. Mechanical ventilation supply ducts in conditioned spaces shall have R4 insulation. <br />Q <br />49. Supply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />Q <br />50. Supply and return air ducts shall have sealed duct joints ;n unconditioned spaces (S. 503.10.2). <br />Q <br />51. HVAC plenums, supply, & return air ducts shall have R-8 insulation. ( Prescriptive and Chapter 5) <br />Q <br />52. Hot water heater(s) shall have (S.504.3, 504.4): <br />a) Separate power, or gas shutoff c) Temperature setting 51200 F. <br />Q <br />b 1987 NAECA Label on tank d Non -compressible R-10 pad unheated spaces, electric only) <br />53. Swimming pools (5.504.5) shall have: <br />Q <br />a Accessible ON OFF switch (pump, heater b Pool cover c Piping insulated to S. 503.11 <br />54. All fireplaces (VIAQ, 5.402.3) shall have: <br />a) 6 square inch combustion air supply duct w/ accessible damper directly connected to the fire <br />box <br />(Washington State Certified Fireplaces may size duct according to manufacturers instructions) <br />b Tight -fitting lass or metal doors c Tight -fitting flue damper <br />Q <br />O 55. <br />Solid fuel buming appliance(s) (VIAQ S.407-2) shall have: <br />a Tight -fitting lass or metal doors b Outside combustion air source directly connected to the fire box <br />WSEC Final Phase Requirements: <br />
The URL can be used to link to this page
Your browser does not support the video tag.