Laserfiche WebLink
r <br />APPENDIX D <br />RETAINING WALL DESIGN <br />Wall design parameters were obtained from the laboratory analysis, explorations, and observations. The <br />anticipated loads on the retaining wall were estimated from the slope stability analysis and our <br />observations of site and slope conditions. A detailed description of wall design methodology and <br />recommended design values have been provided in the body of the report in the Sharing Wall subsection. <br />The attached figures D-1 and D-2 graphically illustrate some of these recommendations. <br />NELSON GEOTECHNICAL ASSOCIATES, INC. <br />10 <br />