Laserfiche WebLink
Ltr. Gonzales (C0409-020) <br />Scptcmbr,r 30, 2004 <br />Pagc 2 . <br />6. Detailing will be required for thc installation of holdowns into existing concrete. <br />Thc shcarwall nailing has not been included within the plans. Thc calculations will not <br />be acceptcd as part of the construction documents. <br />3. Provide smokc alarms per R313 IRC. Show on plans. Alarms shall bc 110 volt with <br />battery back-up .md imerconnected. <br />9. Provide minimum 3" x 3" x�/d' in all braced wall lines per R602.1 I.I IRL • <br />10. Decks shall be positively anchorcd to the primary swct�re and �esigncd for both vertical <br />and lateral loads as applicabla Such attachmcnt shall not be accomplished by the use of <br />tocnails subject to withdrawal. Wherc positive conncction to tFe primary swcture <br />cannot bc vcrificd during an inspcction, decks shall bc sclf-supporting. <br />I l. Guards on open sides of stainaays, raised flonr areas, balconics and rorches shall have <br />inter�nediatc rails or omamental closures which do not allow thc passage of z sphere 4 <br />inches (102 mm) or more in diameter/R312 IRC. A 4-inch (IU2 mm) opcning would <br />allo�v a 4-inch sphcre to pass through. <br />Plcasc prepm�c a response letter showing where each itcm in this con•ection lctter is addressed on <br />the plan sct. <br />Upon resubmiUal of thc drawings, your application �vill bc givcn priority and plan revicw will <br />recommcncc. <br />All required submittals shall be of sufficicnt detail and contain sufiicient information to ensure <br />lhat the proposed stnicwrc �vill bc consuvctcd in compliance ���ith all adopted codes. <br />3incercly, <br />Jeff I Icilma�i <br />Dc�•clupmcnt '1'cchnician <br />PI.UIq'I„�CAVtiI'kNl'1 �tANn'Wp+O.'�111,\RBOH I.ANII � � <br />