CITY OF EVERETT <br />B�IIL�ING INSPECTION DEPARTMENT <br />(206) 259-8745 <br />Date October 10. 1986 <br />James Gaffney Construction <br />1710 - 100th PL SE <br />Everett MA 96204 <br />RE: Owner Carpenter <br />Job Address Lot 20 Darlington <br />Plan Check No. 86/11049 <br />In response to your application for a construction permit, your plans have beer <br />examined and you are,advised that the issuance of a permit is being withheld <br />for the reasons listed below. <br />In order for processing of your application to continue, it will be necessary to <br />provide the Building Department with two new sets of drawings reflecting the <br />corrections requested. <br />Upon resubmittal of the drawings, your application will be given priority and <br />plan review will recommence. <br />Item No. <br />1. I Size, spacing and direction of second floor joists is not shown. <br />2. No support is shown under the north wall of the Master Bath. <br />3. Maximum height is limited to 25 ft, above avera9e existing grade. It <br />appears this could be exceeded. Furnish two hlghest and two lowest <br />existing grades within the footprint of the building and establish <br />finish floor elevation. <br />4. Provide handrails at entry stairs. <br />5, Show exterior line of second floor on Main Floor plan in area of <br />OfPice and Laundry. <br />6. It is not clear what is required at "Special Rearing Points" that are <br />shown on the Foundation Plan. <br />7. 8" x 16" continuous concrete footing is required to have 2- 94 reinforcing <br />Bars. <br />8. � Chimneys to co�form with Chapter 37. <br />� <br />�,r-�,�c ��� <br />�� <br />, k frets, Plans Examiner � � <br />