Laserfiche WebLink
DeSign Build 5ervice5, Inc. _ <br />Engineering & ConStruction Management Pnonc /Fax: (360) 793-9659 <br />26119 - 120th 5L. S.L., Monroc, WA 9fi272 E-maih nc�ideC�dbemonroc.com <br />March 25, 2D15 <br />Alex Golitzin <br />5131 Harbor Lane <br />Everett WA 98204 <br />(425) 353-4140 <br />Plan Check No.: <br />]ob Address: <br />Owner: <br />Ten3nt: <br />Application Date: <br />Proposed Use: <br />Type of workv: <br />Office Set--1�— <br />B1507-OUl <br />5131 HARBOR LN <br />GOLITZIN ALEI(ANDER & JEANNETTE <br />[TenName] <br />7/1/2015 <br />SINGLE FAMILY RESIDENCE <br />SEISMIC UPGRADE IN CRAWL <br />]ob SeL FI(e/Planning Set <br />/9,/i _�. <br />Reviewed For PermiL• Date: S BY: <br />Subject: Seismic Review of your Harbor Lane Residence <br />As requested I have reviewed the seismic capaaty of your home. I met you on-site on March 6 and we <br />reviewed your building struclure exposed in the crawispace. I had previously be given the building plans <br />for the strucWre At the time of my site visit it appeared the area of the ulility room was nol constructed <br />as shown on the plans This might change my recommendation slightly for what we show as wall line x7. <br />I believe part of lhat wall is sheet rocked in the utilily wom. The sheetrock can be removed and replaced <br />with plywood nailed at the required nailing pattern. <br />Based on our discussion I believe your buiiding seismic resistance couid be improved in ihe following <br />ways. I have shown approximate localions of ihe following recommendations on the attached marked-up <br />toundation plan. <br />1. In lhe area �of full heighl foundation walls you can add Simpson UFP10 SDS3 Foundation plates <br />belween your exisling stem wall a�d Ihe 4x10 rim joisls. <br />?, Where there are pony walls or tull height stud walls there can be a number of in�prooements <br />a. Simpson "Titen" Concrele screws can be added to atlach the mudsill lo the tounda�ion <br />and 3x3 washers can be aaded. I recommend a minimum of 4" embedment m the <br />concrete. Where there are double bottom plates Ihis would requlre 8" long screws. <br />[ither Y�' or 51Fi" diameter screws are available. <br />b HDU4 hold-downs can be added at the end of lhe x2 walls. I have shown 2 al Ihe ends <br />oi lhe shorter wall These would be atlached to Qie concrete wilh 518" threaded rod <br />epoxied a minim or 10" inlo the stem wall with Simpson S[T-XP fhese could be added <br />at the ends of other walls, bul ihe amounl of wall at othcr localions does not really <br />require it. <br />c. Add sheelmg to lhe walls to increase shear resistance I have shown the lypical shear <br />wall reywrements on thc atlached summary shcet and on Ihc marked up plan Thc walls <br />that are already sheeled with plywood would no1 need lo be sheeled on lhc inside Ones <br />that do not have plywood slieeling, or where we specify S1-4 walls should have sheeling <br />added. - <br />3 Girder beam allachment to rim joists. I recommend Ihal slraps be added from the rim �oist to the <br />girder at the two girders ihal are shown on the atlached pictures. <br />4 Gtrder beam added supporl — There were four locations where lhe bcam is silting on a small <br />block I recommend ihe block be cul back flush wiih lhe concrete and a 4x6 post be added oH <br />the tooting and attached to lhe concrete wall wilh at least 2-F18"x8" iiten Screws <br />