Laserfiche WebLink
6. <br />� <br />9. <br />10. <br />11. <br />12. <br />13. <br />14� <br />15. <br />1G. <br />17. <br />18. <br />19. <br />� <br />'� <br />PUBLIC WORKS PERMIT COMMENTS <br />Connect :ide sewer per City Standard #601. <br />Connect side sewer per City Standard #'s 601, 602, 604. <br />Connect all rooftop downspouts to ihe side sewer. <br />Connect rooftop downspouls lo the drainage system provided for this lol. <br />Rooftop runoif must be discharged to a roof downspout in(iltration system per City of Everelt Storm <br />Manual 3-2.0.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachmenl for <br />more details. <br />The conlractor musl meet with the Public Works Inspector lo discuss potential drainage routing prier to <br />beginning ihe project. <br />Install erosion control measures as delermined by lhe Public Works inspector, such as silt tence, slra�v <br />bales, swales, or erosion blankets. <br />Inslall erosion conlrol measures per Cily of Everetl Slandards for small parcels <br />Remove erosion control measures upon completion of the project prior to final approval of the permit. <br />All excavaled malerial trom foundation, sidewalk and driveways shall be hauled to an approved, <br />permilled site. No wasting of material is allowed on lhis building lot. <br />No dirt, mid, rocks or debris to be tracked onto roadway. <br />No building materials lo be slacked on sidewalks and sidewalks to be kept clean and op�n for <br />pedestrian lravel. <br />Adjusl waler meler box 1" above sidewalk grade. <br />Remove and replace curb, gutler and sidewalk as per City oi EvereU Slandard Plan #'s 305A & 30G on <br />lhis proposal's (rontage as direcled by the Public Works Inspeclor (i.e. all unused driveways and any <br />broken or damac�ed area musl be replaced). <br />Install a Type I concrele driveway per City of [veretl SlandaM #307. <br />Pave driveway irom the fronl property line out lo thc s!reet paving. <br />20. Contact the _ <br />sewer services. <br />21 <br />22. <br />Waler Dislricl (or connecling provisions for lhis building's waler and <br />A calch basin as per Cily Slandard Plan i/402 with a gas trap per Slandard Plan q410 is required for the <br />parking area. <br />I( a sewer pump system is to be installed, the pressurc line must discharge into a private manhole, then <br />c�ravity flow across the public right-o(-way <br />23. A sprinklcr system is required for this buildinr, in compliance wilh lhe requirements of NFDA Standards <br />13D. <br />PWComm:nls -� >�� <br />I� <br />�\ <br />