Laserfiche WebLink
� <br />I....� � <br />� <br />FRANKLIN <br />ENGINEERING <br />MEC�P.P11C�1L CGNSULT:PIG <br />November 10, 2008 <br />RE: Goodrich TI <br />6700 Hardeson Rd <br />Everett, WA <br />Suite 202 <br />F��kland, 1'IA 98033 <br />.-, <br />� __ .. ,_� <br />PA?( 425 827-G�c2 <br />hvac�ofra^,�ime�,7.c.m <br />gC���•011 <br />ENVELOPE SUMMARY <br />Tenant Imprnvement of existing Office/Warehouse. Both Office and Warehouse to be <br />fully heated. Project complies with 2006 WSEC using the Component Performance <br />approach with heating by Other Fuels. <br />Vertical Glazing: Double pane, 1/2" space Air, low-e10�10j, fixed. Or certified tested <br />assembly per NFRC. U=0.55, default (Table 10-6). SHGC=0.45. <br />Doors (Opaque, Man & Overheadl: Insulated metal, U=0.60, default (Table 10-61. <br />Other Roof: R-19 rigid insulation, plus cover board. U=0.046, calculated. <br />Wall �l1 (Opaque, Exterior, Floor to 9'-0" AFF at Existing Office): Concrete, min. 6" thick, <br />furred with metal studs, 3-1/2", 24" oc with R-11 batt insulation, U=0.115, <br />calculated. <br />Wall #2 (Opaque, Exterior, 9'-0" AFF to Roof at Office; 10'-0" AFF to Roof at <br />Warehausel: Concrete, min. 6" thick, with R-19 batt insulation stickpinned to <br />concrete, U=0.053 calculated. <br />Wall #3 (Opaque, Demising Wall1: Metal studs, min. 5-1 /2", 24" oc with R-19 batt <br />insulation, U=0.094 default (Table 10-5A). <br />Wall #4 (Opaque, Exterior, Floor to 10'-0" AFF at Warehouse): Concrete, min. 6" thick, <br />with .�o insulation, U=0.61 default (Table 10-58). <br />'1ro <br />