Laserfiche WebLink
( <br />FRANKLIN <br />ENGiNEERING <br />��.'[CPi-��,A9C�1 CONSULT1Nc_. <br />November 5, Z012 <br />RE: Umbra TI <br />6707 Hardeson Rd <br />Everett, WA 98203 <br />G7_5 i�our C.h /,vc���': <br />Suite 202 <br />n n, ,', <br />�rV:I,,�,J. WP, _�_C)�., <br />-� X I Zt l-00&- <br />� =;?5 92?-'.3: <br />FAx 425 82" `,'.0 ' <br />�-,v<;��r�`r.ank�in,_,., ,. _. . <br />ENVELOPE SUMMARY <br />Conversion of existing semi-heated Warehouse area into conditioned Warehouse. Project <br />complies with 2009 WSEC using the Component Performance approach. <br />Other Roof: Existing R-19 rigid insulation above roof deck. U=0.05, calculated. <br />Walls (Opaque, Exterior, Floor to Roof): Concrete, min. 6" thick, with R-30 insulation <br />stickpinned to concrete, U=0.035 calculated. <br />Doors (Opaque, Man): Insulated metal, U=0.60, default (Table 10-6). <br />Doors (Opaque, Overhead 9x10): Uninsulated metal, U=1.20, default (Table 10-6). <br />Doors (Opaque, Overhead 12x14): 2" insulated, R17.5 solid polyurethane core, Wayne <br />Dalton Thermospan 200-20 or equal, U=0.057 per manufacturer. <br />Floor Over (Soffit at South Loading Dock): Metal joist with R-21 batt insulation. <br />U=0.11, default (Table 10-4A). <br />Slab on Grade: No Insulation, F=0.73, default (Table 10-2). <br />Vertical Glazing (Fixed): Double pane, 1/2" space Air, lo�v-e, aluminum frames. U=0.65, <br />default (Table 10-6). SHGC=0.40. <br />Vertical Glazing (Entrances): Double pane, 1/2" space Air, low-e, aluminum frames. <br />U=0.78, default (Table 10-6). SHGC=0.40. <br />Overhead Glazing: Double pane, U=1.08, default (Table 10-6). <br />Please note that these values are minimum insulation requirements for code compliance. � <br />Higher insulation values may be installed. SHGC = Solar Heat Gain Coefficient ! <br />,,, , <br />