My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7000 HARDESON RD 2018-01-02 MF Import
>
Address Records
>
HARDESON RD
>
7000
>
7000 HARDESON RD 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2022 4:02:56 PM
Creation date
2/20/2017 11:24:25 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7000
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
472
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Quadrant 6-917-10260 <br />12 April 1996 Page 7 <br />0.1 percent of the height of the wall, the soil pressure will be less than if structurally restrained <br />from lateral movement at the top. Retaining walls an be designed using an equivalent fluid <br />pressure of 35 pcf (pounds per cubic foot) and 50 pcf be used for yielding and non -yielding <br />backfllled walls, respectively. Allowable passive pressure values should be designed for on <br />I equivalent fluid weight of 350 pcf neglecting the upper 1 foot of soil and assuming a factor of <br />safety of at least 1.5. These equivalent fluid pressures assume that the backfill is compacted <br />to 90 percent of the modified Proctor maximum dry density (ASTM:D 1557). We recommend <br />that AEE be allowed to review these design values, and modify them if necessary, if they are <br />to be applied to walls greater than 12-feet in height. We recommend an allowable base friction <br />value of 0.4, utilizing a factor of safety of 1.5. <br />The above equivalent fluid pressures are based on the assumption of a uniform horizontal <br />backfill and no build-up of hydrostatic pressure behind the wall. Surcharge pressures due to <br />sloping ground, adjacent footings, vehicles, construction equipment, etc., must be added to <br />these values. Sloping surcharges within a distance from the top of the wall equal to the height <br />of the wall should be factored into the wall design. The equivalent lateral surcharge of the <br />slope within the distance previously described should be equal to % or % the height of the <br />slope times a unit weight of 130 pcf for active and attest conditions, respectively. A minimum <br />width of 2 feet of clean, granular free -draining material should extend from the footing drains <br />at the base of the wall to within one foot of the ground surface, to prevent the buildup of <br />hydrostatic forces. Wall backfill should consist of aggregate with less than 3 percent passing <br />the U.S. No. 200 Sieve, based on that fraction passing the U.S. No. 4 Sieve, with at least 30 <br />percent retained on the No. 4 Sieve. The upper foot of wall backfill should be silty soils to cap <br />the free -draining fill and reduce infiltration adjacent to the wall. Filter fabric should be placed <br />over the top of the drainage materials to segregate it from the overlying silty soils. It should <br />be realized the primary purpose of the free -draining material is reduction of hydrostatic <br />pressure. Some potential for moisture to contact the back face of the wall may exist event <br />with this treatment, which may require more extensive waterproofing to be specified for wells <br />which require interior moisture -sensitive finishes. <br />Service pit walls do not require clean, granular free -draining material for backfill. We do not <br />anticipate excessive hydrostatic pressures as concrete pavement and building slabs will greatly <br />reduce the infiltration of water. Fill material should conform to specifications from Section 4.2 <br />'Structural Fill". On -site soil would he permissible provided adequate compaction can be <br />A achieved. <br />To prevent the buildup of lateral earth pressures in excess of the above design pressure, <br />overcompaction of fill immediately behind the walls should be avoided. Only light self-propelled <br />or hand compaction equipment should be allowed within close proximity to the wall. Bacltflll <br />placed behind walls should be placed in accordance with our recommendations for structural <br />fill, except the maximum compacted fill density should not exceed 90 percent of the modified <br />Proctor maximum dry density. <br />j �2L <br />
The URL can be used to link to this page
Your browser does not support the video tag.