My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7425 HARDESON RD BASE FILE 2016-01-01 MF Import
>
Address Records
>
HARDESON RD
>
7425
>
BASE FILE
>
7425 HARDESON RD BASE FILE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/16/2017 11:03:58 PM
Creation date
2/20/2017 11:52:59 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7425
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1311 Insulation <br />1371.1 InsWlWtion Requirnments: All insulation materials <br />shall be installed accordirg to the manufadurer's instructions <br />to achieve proper densdies, maintain clearances, and maintain <br />undorm R-values. To the mazmum extent possible, insulation <br />shall e�ctend over the full component area to the intended R- <br />value. <br />7317.2 RooflCeiling Insulation: Open-bbwn or poured loose- <br />fill insuiation may be used in attic spaces where the slope d <br />the ceiling 5 not more than 3/12 and there is at least thirty <br />inches of clear distance from the top of the bottan chad of the <br />lruss or ceiling jdst to the underside of the sheathirg at the <br />roof ridge. When eave vents are ireta!led, baf9irg of the vent <br />openings shall be pnvided so as to de� lect the incoming air <br />above the surtace cf the insulation. <br />Where lighting fixtures are recess� irrio a suspended or <br />exposed grid ceiling, the roof/ceiling assembly shall be <br />insulated in a lowGon other than directly on the suspertled <br />ceiling. <br />Exception: Type �C rated recessed hgMing 5xtures. <br />Where installed in wood framing, faced batl insulation <br />shall be face staoled. <br />1371.3 Wall Insulafion: Extenor wall cavities isolated during <br />framing shall be fully insulated to the levds of the surtounding <br />wa�s. When installed in wood traming, faced batl insulation <br />shall be face stapled. <br />Above grede extenor insulation sh�l be protected. <br />1311.4FIoorinsulation: Floorinsulationsha�lbeinstalledin <br />a permanent manner in substaMial contact with ihe suAace <br />being ireulated. Insulation supporis shall be installed so <br />spacing is not more than twenty4our inches on center. <br />Instatled insulation shall not block the aiAlowthrough <br />toundation vents. <br />13I1,551ab•On•GradeFloor: Slalron-gradeinsulation <br />installed inside the foundation wall shall extend dowmvard from <br />the top of the slab a minimum distance of �venry-fov mches a <br />to the top of the fooling, whichever is less. Insulation installed <br />outside the foundation shall exlend downward a minimum d <br />twenty-four inches or to Ihe fmstline, whichever is greater. <br />Above grade insulation shall be protected. <br />Ezception: Fa monolithic slabs, the insulation shall <br />extend dowmvard (rom Uie top of the slab tothe <br />6oriom of the fooling. <br />131 t.6 Radi�n[ Floors (on or below grade): Slatrorngrade <br />insulation shall extend dowrnvard (rom ihe top ot the slab a <br />minimum distance of thirty-six inches or dowrnvard to the top d <br />ihe footing and horizontal for an aggregate o( not less than <br />thirty-six inches. <br />If required b�� tlm build�ng offcial where soil conditions <br />wanant such msulation, ihe entire area of a radiant Boor shall <br />be thermally isolaled from the sdl. Where a soil gas control <br />syslan is provided below the radiant fbor, which results in <br />inereased conveclive flav bdow the radiant floor, the radiant <br />Ooor shall be thertnally isolated from the sutrflow gravel layer. <br />1372 Glaang and Doors <br />1J12.1 Standard Procedure for Determination of Glazing <br />and Door U•Factors: U-factors'orglazing and doors shall be <br />determincd, certdied and labeled in aanrdance wdh Slandard <br />RS-31 by a certifed independent agency licensed by the <br />IJational Fenesiration Rffiing Candl (NFRC). Compliance <br />shall be based en the Residen6al or the Nonresidential Model <br />Size <br />ProtlUGI sanples usE� ror u-tactor tletertninations shall be <br />production lire units or representatNe of unAs as purchased by <br />the consumer or contractor. Unlabeled daang and dows shall <br />be assigned the default U-factor in Sxtion 20�6. <br />1312.2 Solar Heat Gain Cce�cient and Shading <br />Ccefficient Solar Heat Gain Ccefficient (SHGC), shall be <br />determined, certified and labeled in accordance with lhe <br />National Fenectration Rating Cwndl (NFRC) Standard by a <br />certified, independent agency, licensed by the NFRC. <br />Ezception: Shading coeffideMs (SC) shall be an <br />acceptade alternate for canpliance with solar heat <br />gain wefident requirements. Shading coeffiaeMs <br />for glazing shall be taken fran Chapter 27 of <br />Standard RS-27 w from the mawfadurer's test data. <br />7313 Moisture Control <br />1313.7 Vapor Retarders: Vapor reWrders shal� be installed on <br />Ihe wartn side(in winter) of insulalion as required by this <br />section. <br />ExcepBon: Vapor retarder insta0ed with not mae <br />than 1l3 d the nominal R-value between d and the <br />conditioned space. <br />1313.2 RooflCeilingAssemblies: Roof/ceiling assemblies <br />where the venlilation space abwe lhe insulation is less than <br />an average of twelve inches shall beprovided vnth a vapor <br />retarder. Roof/ceiling assemblies whhout a vented airspace, <br />where neither the roof deck nor the roof structure are made of <br />wood, shall provide a continuous vapor retarder with taped <br />searns. <br />Ezception: Vapa retarders need not be provided <br />where all of the insulation is installed beiween the <br />roof mcmbrane and the structural roof deck <br />1313.3 Walls: Watls separating conditioned space from <br />imconditloned space shall be provided wdh a vapor retarW_r. <br />1377.4 Floors: Floors separating conditioned space from <br />unconditioned space shatl be provided with a vapor rE,arder. <br />1313.5 Crawl Spaces: A ground cover of six mil (0.006 inch <br />thick) black polyethylene or apprrn�ed equal shall be laid over <br />the ground wilhin crawl spaces. The ground cover shall be <br />ovedapped twelve inches mininum al the joints and shall <br />eMend to the (oundation wall. <br />Exception: The ground cover may be omitted in <br />crawl spaces if the crawl space has a concrete slab <br />floorwdh a minimum thickness ol thrre and one-half <br />inches <br />1374 Air Leakage <br />7314.1 Building Envelope: The requiremeMso(thissection <br />shall apply to 6uilding elenents separa6ng conditioned 6om <br />unconditioned spaces. Ezteriorjoints aro�nd windows and <br />door lrames, openings between watls and foundation, between <br />walls and roof and wall panels; openings at penetrations of <br />Wility services through walis, floas, and roo(s; and all other <br />openings in the building envelope shall be sealed, caulked, <br />gasketed, a weather5ripped tc limit air leakage. <br />1314.2 Glaang and Doors: Doors and operable glazing <br />separating conditioned from urxonditionetl space shall be <br />wea;herstripped. Fixed windows shall be tight fitting with glass <br />retain�vi by siops with sealarri or caulkirg all around. <br />Exception: Openings that are required to be fire <br />resistant <br />1314.3 Building /.ssemblies Used as Ducts or Plenums: <br />Building asse��lies used as ducts a p�enums shall be sealed, <br />cau!ked, :3nd gasketed to limit air leakage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.