Laserfiche WebLink
FRANKLIN <br />ENGINEERING <br />MECHANICAL CON5ULTING <br />February 28, 2005 <br />RE: Messier Bugatti TI <br />025 Fourth Avenue <br />Suite 202 <br />Kirkland WA 95033 <br />PH 425 527-3324 <br />FAX 425 527-6252 <br />hvac&Dfra nklineno.com <br />RU5o -017 <br />ENVELOPE SUMMARY <br />Heated space applies to entire building. <br />Vertical Glazing: U=0.75, SC=1.0. Unlabeled glazing - 1/2" space Air, fixed, default. Or <br />certified tested assembly per NFRC. <br />Doors (Opaque, Man and'fruck): Uninsulated metal, U=1.2, detault. <br />Other Roof: Built-up roof with wood deck; 2x6 wood, 24" oc with K-I I batt insulation; metal <br />beams, min. 9'-0- oc. U=0.088, calculated. <br />Nall Type I (Opaque, Exterior, Floor to Ceiling): Concrete, min. 6" thick, furred with metal <br />studs, 3-1/2", 24" oc with R-11 batt insulation, U= 0.11, calculated. <br />Nall Type 2 (Opaque, Exterior, Ceiling to Floor/Roof Structure Above and Above Bare <br />Concrete in Warehouse): Concrete, min. 6" thick, with R-19 batt insulation stickpinned <br />to concrete, U=0.05, calculated. <br />Wall Type 3 (Opaque, Warehouse, Floor to 8'-0" AFF): Concrete, min. G' thick, no <br />insulation, U=0.61, netault. <br />Slab on Grade: No Insulation, F=0.73, default. <br />Please note that these values are minimum insulation requirements for code compliance. <br />Higher insulation values may be installed. <br />SC = Shading Coefficient <br />