My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2715 HARRISON AVE 2018-01-02 MF Import
>
Address Records
>
HARRISON AVE
>
2715
>
2715 HARRISON AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2022 10:31:13 AM
Creation date
2/21/2017 1:11:35 AM
Metadata
Fields
Template:
Address Document
Street Name
HARRISON AVE
Street Number
2715
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE <br />REQUIRED Er <br />INSPECTION IMPORTANT: Supply Information and check appropriate circles In the shaded boxes. <br />APPROVED Disregard topics that don't describe your building or equipment. DO NOT place checks In <br />the two left columns. <br />M,10 <br />WIN <br />C <br />l <br />Exhaust ventilation shall be provided for each dwelling unit (VIAO, S. 303): <br />Location Minimum at .25 w.g. MfrJmodel <br />Fan label CFM(.1 W.G.) <br />Kitchen fan <br />100 CFM <br />t JEwT> 6IC (,V <br />100 <br />Bathroom fan( 1 <br />50 CFM <br />oeAY- 7 je. QT gb <br />5i7 <br />Bathroom fan( <br />50 CFM <br />Bathroom fan(_) <br />50 CFM <br />Laundry fan <br />50 CFM <br />NeWn109 CAT5 <br />5� <br />50 CFM (1-2 bedrms) <br />Whole house fan O 80 CFM (3 bedrms) <br />(choose one) <br />0 100 CFM (4 bedrms) <br />rs <br />Whole house fan: Location LAN Sone rating 15if <br />•-"-�-,t•� (5att�tan`tAOaaf�"l�C <br />ceiling) <br />Whole house fan is listed/labled "for Continuous use". <br />C) Whole house fan wiring for control routed to central location (dehum/distat only). <br />re Whole house fan also serves as a kitchen or bath spot fan. Yes) No <br />(if a spot fan Is designated as a whole house fan, the capacity shall ba th(3 targerCFM requirement.) <br />v Whole house fan shall run continuously: Kitchen rate 25CFM: Bath'&laundry rate 20CFM <br />r Integrated forced -air furnace ventilation (VIAQ Code, S. 303.1.2(b))shall be synchronized with a <br />whole house Ian to supply fresh air to the dwelling: O Yes ONO <br />0 if yes, a 6" diameter outside air inlet duct w/ motorized dampb'shall run from the building A <br />exteriorto the furnace ratum plenum and limft the ventiltion rate to between .35 - S ACH ,` ," , <br />0 Mod"Akatlons to the above integrated forced air system may require performance testing Ifit .;� . <br />manner acceptable to the building official, to demonstrate .35 -.5 M Changes/Hour. <br />Mechanical ventilation fan ducts shall be z 4" and properly sized (VIAO, Table 3-3). <br />2]Fresh air shall be provided for each dwelling unit as follows (Vt <br />I -Each bedroom: Tested, screened, controllable, through -wail 0 <br />recreation room; One wall port as specified for bedroon <br />Pf-Other enclosed "habitable" rooms: One wail port as spechieE <br />"Overall living areal One wail port as specified for bedrooms. <br />H) OR OCentral forced air furnace which delivers outside makeu; <br />zE)Recessed lighting fixtures (S. 502A.4) shall comply w/ one or tn0. <br />0 IC rated, no slots or holes in cans, caulked or sealed betwee <br />0 rated with labee certifying an ASTM E283 tested aideakage <br />CI Any UL listed fixture enclosed by a 1& gypboard box or othE <br />wl 1/2' clearance to combustabies, and 3" clearance to insuk <br />Page 4 of 6 <br />1 <br />,FM ± k <br />actured box <br />WSEC Framing phase requirements: <br />Inspected by Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.